background image

Energier pro User Manual

Energier pro bi-directional inverter is a sine wave inverter which generates a near perfect sinusoidal AC wave power output that is very 
similar or even better to what you could get from your utility grid. Pure sine wave can guarantee the correct function of sensitive 
equipment (computer, laser printer, TV etc) or most demanding inductive load. Also, your home appliances will work smoother, cooler 
and more efficient, such as fridge, microwave and power tools.

The charger automatically starts up when qualified AC power is presented either from grid or generator, charging the stationery or 
service battery connected, featuring:

The built-in charger of Energier pro bi-directional inverter was designed with high power, which can quicklycharge a battery within 6-8hrs.

Provided with outstanding surge power capability and low frequency transformer, Energier pro bi-directional inverter is suitable for 
heavy inductive load like refrigerator, coffee maker, microwave, power tools, air conditioner etc.

2.2 Inverter

2.3 Battery Charger of stationery/service battery

Pure Sine Wave 

High surge power

Powerful Charger

Fitted with multistage charging algorithm (bulk-absorption-float-recycle), the built-in charger of the Energier pro bi-directional inverter is 
designed to charge batteries quickly and fully. Microprocessor controlled charging algorithm with variable absorption charging times 
guarantees the optimal charging for batteries of different discharged state. 

Float charging and Recycle charging programs guarantee your batteries receive proper maintenance in case of prolonged connected. 

Multi stage sophisticated charging algorithm for lead acid battery

Battery temperature is a key factor in correct charging, the charging formula must be adjusted (automatically and in real time) according 
to the actual battery temperature to ensure that battery are fully charged but not overcharged or undercharged. All charging voltages 
recommended by battery manufacture are in fact only applied at 20

℃ 

- 25

The TS (battery temperature sensor) supplied with Energier pro bi-directional inverter measures the temperature of battery and 
automatically makes adjustments at real time to properly charge your batteries at compensation rate of – 4mv / 

℃ 

/ cell. In case of 

BTS was not present, Energier pro bi-directional inverter will use 25

 as default setting.

Battery temperature compensation

Summary of Contents for Energier Pro Series

Page 1: ...User Manual Energier Pro series Bi directional inverter TBB Power CO ltd www tbbpower com A3 1...

Page 2: ...ergier pro User Manual WARNING FIRE HAZARD SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON COMBUS TIBLE SURFACE ONLY CAUTION THE DC AND AC BREAKER MUST HAVE BEEN TURNED OFF BEFORE SERVICING MADE IN CHI...

Page 3: ...the inverter 2 Please connect positive terminal of battery to input of the inverter 3 Please connect negative terminal of battery to input of the inverter 4 Please use the shortest cable and ensure t...

Page 4: ...el 6 2 9 Weak Grid 6 2 10 Solar mode 7 2 11 Gen mode 7 2 12 Power Save Mode PS mode 7 2 13 AGS Automatic Generator Start 8 2 15 Vision Lite control center 9 2 16 RCF remote module optional device 9 2...

Page 5: ...Type 4 6 Equalization EQ 4 7 Power Save mode PS mode 4 8 GEN mode 4 9 AC input current setting 5 Pre Installation 5 1 Material list 5 3 Wiring recommendation 6 Installation and Connection 6 1 General...

Page 6: ...sulphation Charging 42 8 Specification 44 9 Trouble Shooting 46 9 1 LED indicator on front panel and audible alarm 46 9 2 LED indicator on Remote 47 9 2 1 Operating status 48 9 2 3 Load percentage ba...

Page 7: ...electric shock make sure all cables selected with right gauge and being connected well Smaller diameter and broken cable are not allowed to use 1 2 3 Please do not put any inflammable goods near to in...

Page 8: ...endent power systems The product was delivered with following equipment Energier pro bi directional inverter user s manual TS battery temperature sensor VS battery voltage sensor optional RCF Remote m...

Page 9: ...o a single enclosure Meantime multiple power management functions devices make it convenient to compose different advanced hybrid independent power systems Twin AC input devices TAI is available with...

Page 10: ...ve High surge power Powerful Charger Fitted with multistage charging algorithm bulk absorption float recycle the built in charger of the Energier pro bi directional inverter is designed to charge batt...

Page 11: ...tically adjust its output power making it suitable for the battery capacity selected The charging current default threshold rate is 15 of the battery capacity I 0 15C chosen 2 4 Slave Charger When vol...

Page 12: ...e applied to Flooded and OPZS batteries As a protection the EQ mode will automatically disable if you select either LFP GEL OPzVor AGM as battery type 2 7 Manual Equalization Deep discharge of a lead...

Page 13: ...nergier pro bi directional inverter offers the approach to fully adjust this entry level Please refer to chapter 7 11 for detail instruction You can also achieve this programming through optional Visi...

Page 14: ...er has an internal or external AGS that can be used to start the Generator upon battery runs low To use this function the Generator needs to have automatic start function Upon battery runs to low volt...

Page 15: ...ed input either grid or generator It can automatic allocate the power available with AC source either grid or genset using whatever extra for charging thus avoiding grid or generator to be overloaded...

Page 16: ...ttery discharging to low protection alarm level through AGS Energier pro bi directional inverter will send signal to start Diesel Generator connected After detecting output of Diesel Generator was sta...

Page 17: ...bi directional inverter The default setting of this dry contact output was battery low voltage It will activate once the voltage was detected dropping to preset level This dry contact can be used for...

Page 18: ...ro bi directional inverter was fully programmable through PC of following parameters Battery charging parameters AC input range Switching parameters Battery configuration capacity type and low voltage...

Page 19: ...can set its own preferred low voltage disconnect level Energier pro bi directional inverter will shut down upon battery voltage reach the preset level preventing battery to be over discharged or disc...

Page 20: ...er Rated DC voltage 24V Rated output power 5000VA 4500W Rated charge current 90A With built in TAI field figure CF series name explanation 50 12 08 16 20 30 40 60 80 50 20 15 25 30 40 45 60 90 50A 20A...

Page 21: ...al 15 1 CF0825L CF0815M CF1240L CF1220M CF1650L CF1625M 2 CF2060L CF2030M CF2015S CF3090L CF3045M CF3020S CF4030S 3 CF5090M CF6050S CF8060S CF5040S 3 Structure 3 1 Product drawing 3 1 1 Energier pro b...

Page 22: ...Energier pro User Manual 16 3 1 2 RCF remote 3 1 3 Vision Lite 3 1 4 AGS 3 1 5 TAI...

Page 23: ...Energier pro User Manual 17 2 CF2060L CF2030M CF2015S CF3090L CF3045M CF3020S CF4030S CF0825L CF0815M CF1240L CF1220M CF1650L CF1625M 3 2 1 Energier pro bi directional inverter 3 2 Product size...

Page 24: ...Energier pro User Manual 18 3 CF5090M CF6050S CF8060S CF5040S 3 2 2 RCF remote 3 2 3 Vision Lite...

Page 25: ...Energier pro User Manual 19 3 2 4 AGS 3 2 5 TAI...

Page 26: ...Model CF 2000VA 4000VA Model 4 Pre installation Configuration Front Panel A B D C E F Gland for remote control cable Battery cable through hole Gland for AC output Battery cable through hole Gland for...

Page 27: ...ion is being prepared for configuration through dipswitch In case you bought Vision Lite or Rapconfig please refer to Vision Lite or Rapconfig for detail introduction Loose screws and remove the top p...

Page 28: ...AGS Interface AC Input terminals Auxiliary terminals Battery terminal Remote Interface B D C Battery terminal Slaver Charger terminal AC Output terminals F G E H I K J M N L Voltage Sensor terminals...

Page 29: ...Input terminals DIP Switches Remote Interface BTS Interface B D C Battery terminal Battery terminal Slaver Charger terminal F G E I J L K N O AC Output terminals H M Auxiliary Out terminals Voltage Se...

Page 30: ...s AC Output terminals RS485 Interface DIP Switches B D C Battery Terminal Battery terminal Chassis Ground F G E I J L K N O Generator Input terminals H P BTS Interface M AGSTerminal Voltage Sensor ter...

Page 31: ...rger to get higher charging current However please make sure the current did not exceed 0 2C 20 of battery capacity 1 If you choose battery capacity at 200 AH you could get charging current of 15 x200...

Page 32: ...le with only electrical parameter It may vary according to discharge current battery healthy etc 4 4 Low Voltage disconnect LVD Please refer to following chart for all setting of DIP Switch DIP Switch...

Page 33: ...tery type at the DIP Switch 4 5 following please find the list of available battery type and charging voltage 4 5 Battery Type Through switch dip switch 6 with a cycle from OFF to ON to OFF you could...

Page 34: ...er Save mode PS mode Through DIP Switch 1 and 8 you could configure the system to different modes for different appliance For explanation please refer to chapter 2 11 Through RCF supplied you can set...

Page 35: ...g Forced air 5 1 Material list Please install the equipment in a location of Dry Clean Cool with good ventilation 5 2 Location Please find the following minimum wire size In case of DC cable longer th...

Page 36: ...er performance of the equipment On the AC output side we recommend connecting the output from Energier pro bi directional inverter to a suitable Residual Current Circuit Breaker and Circuit Breaker Th...

Page 37: ...example install on wall please choose a flat surface and with 4XM6 to fix the unit securely Steps for 800 4000 VA models Step 1 Fix the widget on the wall with 4 M6 screw Step 2 Pre installation pictu...

Page 38: ...ansion screw Buckle the pothook of the unit into the expansion screw that was already fixed on the wall Step 3 Use the other 2 M6 expansion screws to fix the unit on the wall Please make sure Energier...

Page 39: ...Energier pro User Manual 33 CF 2000 VA 4000 VA Model CF 5000 VA 8000 VA Model...

Page 40: ...erminal of service battery might cause the slave charger fail to perform charging Use 2x2 5 mm wire Connecting the POSITIVE terminal of the starter battery to the terminal marked S output on central p...

Page 41: ...f warranty The neutral output of Energier pro bi directional inverter is automatically connected to earth upon no external sources is available Once external AC sources present the ground relay will o...

Page 42: ...chment Please notice the cable supplied is around 300cm Do not pull cable too hard avoid loose contact loose Pull through the VS cable through gland and connect it on port marked Voltage Sensor Please...

Page 43: ...able please refer to following figure Connect the Vision Lite to the RS485 interface of Energier pro bi directional inverter with the cable please refer to following figure 6 6 Install the RCF remote...

Page 44: ...ng the output on terminal marked OUT Please double check the polarity of the input and output Wrong connection will damage the equipment and it is out of warranty TAI need to be connected with Energie...

Page 45: ...not present Energier pro bi directional inverter will go to inverter mode automatically In case the user does not want to use the inverter mode but wants the batteries to be fully charged the CHG ONLY...

Page 46: ...mode feeding the power to load and meantime battery charger will start work The bypass LED and charger LED on front panel will illuminate The AC in LED and Charger LED on remotewill illuminate While c...

Page 47: ...5 on remote will illuminate The charging LED on front panel will flash The Bulk Battery SOC 25 LED and ABS Battery SOC 50 LED on remote will illuminate Along with more energy being charged into batter...

Page 48: ...on sealed batteries Energier pro bi directional inverter includes a manual equalization program that can be used if recommended by battery manufacturer Through the dip switch at central panel you can...

Page 49: ...to OFF after each time s equalization Battery manufactures recommendations on equalization vary Always follow the battery manufacturer s instructions so batteries are properly equalized As a guide a h...

Page 50: ...150 200 CF2015S CF3020S CF4030S CF8060S TAI 20 s 800 1100 1000 1200 1300 1200 1600 1600 1450 2000 2500 2200 3000 3500 3200 4000 4500 4000 5000 5000 4500 6000 7000 6000 8000 Bypass range 89 92 95 3 1...

Page 51: ...e 12VDC and 24Vdc model only Slave Charger 4mV cell Temperature compensation Other Data Transfer time 2 s 15ms Battery low Dry contact Battery connector M6 x 2 M8 x 2 440 232 5 95 10 5 11 65 11 9 18 1...

Page 52: ...lash flash Float Stop charging Power Save mode Battery low voltage flash Battery overvoltage flash Inverter overload flash Inverter overtemp Alarm Mode Protection mode beep 0 5s every 1s beep continuo...

Page 53: ...ge Function Constant voltage Constant current Float EQ Inverter ON Power Save mode Battery overvoltage Inverter overload Inverter overtemp Bypass overload Over charging AEA limited flash Battery low v...

Page 54: ...se polarity Solution Replace PCB 9 3 1 No output first power on Phenomenon 4 No output fault and overload lights illuminate Reason Overload shutdown Solution Reducing load and switch on again Phenomen...

Page 55: ...he load was fluctuating Solution Change work mode to normal mode 9 3 5 Normal mode or Charger Only mode not working Reason 1 The work mode setting on Energier pro bi directional inverter and on RCF wa...

Page 56: ...POWER CO LTD Web www tbbpower com Tel 86 592 5212299 Fax 86 592 5796070 Email service tbbpower com TBB POWER GmbH Web www tbbpower de Tel 49 0 211 6413 7949 Fax 49 0 211 6415 0003 Email info tbbpower...

Reviews: