17
Marchesan Implementos e Máquinas Agrícolas “TATU” S.A.
RCP² 1500
Set-up instructions
Assembly of the oil level marker with breather
B
B
C
C
A
A
D
D
E
E
Maximum
Maximum
Minimum
Minimum
• Double distributor:
Place the valve with breather (A) to
replace the plug (B) on the upper part of
the distributor.
Check the oil level in the distributor,
keep the rotary cutter leveled and remove
the side plug (C).
NOTE The suitable level is when the
oil reaches the hole of the side
plug (C), being the rotary cutter
in a flat place.
Use only SAE 90 oil.
• Gearboxes:
Remove the plugs (D) from the gearboxes and place the oil level markers with breather
(E).
At this moment, check the oil level by just placing the marker, without tightening it, in
order to reach the lower mark (minimum level). The upper mark (maximum level) is reached
when the markers are tightened.
The oil level must be adjusted according to the marker indications, being the equipment
on a flat place.