Menus
Instruction Manual: Professional Receivers and Decoders (IRD)
Page C-11
ST.TM.TT1220.1
C.3.17
RS232 Setup Menu
The RS232 setup menu allows the user to enter the configuration of the
two RS-232 ports on the TT1220, the remote port and the LS data port.
Table C.19: RS232 Setup Menu
Display title: ADV: RS232 SETUP
Description
Section
Remote>
Enters the remote setup submenu
C.3.18
LS Data>
Enters the LS data setup submenu
C.3.19
C.3.18
Remote Menu
The remote menu contains the parameters that has to be configured for a
remote control computer / device to work correctly.
NOTE…
TANDBERG Television’s remote control or software upgrade software requires the use of a
null-modem (crossed) RS-232 cable, not a straight cable.
Table C.20: Remote Menu
Display title: SET: REMOTE
Description
Section
Baud rate
Sets the baud-rate for the communication with the external device.
1200, 2400, 4800, 9600, 19200, 38400, 57600 and 115200 baud
selectable.
Data bits
Sets the number of data bits. 7 or 8 selectable.
Stop bits
Sets the number of stop bits. 0.5, 1.0, 1.5, and 2.0 selectable.
Parity
Sets the parity. The TT1220 only accepts “none”
Flow control
Sets the flow control. None or s/w selectable.
CAUTION…
When software upgrading the TT1220 via RS-232 and the TANDBERG Television software upgrader
(UPGRADE.EXE), it is important that the baud rate is set to 38400, the data bits to 8, the stop bits to 1,
the parity to none, and the flow control to none. If this is not the case, the UPGRADE software might fail
to work.