Operating the Equipment Remotely
Instruction Manual: Professional Receivers and Decoders (IRD)
Page 4-5
ST.TM.TT1220.1
4.1.5
OAC Lockout
Overview
Once the unit is in OAC control mode, it is possible for the remote control
operator to issue a local lockout command to the decoder. This will
effectively deny the local user access to configuring the unit.
However, if a situation occurs whereby the local user needs to regain
control over the unit, without a local lockout relinquish command being
sent from the OAC control PC, a four digit PIN may be entered through the
keypad.
The PIN is created at lockout time by the user. To obtain the PIN, please
consult the person responsible for the administration of the unit.
NOTE…
TANDBERG Help Desk will not be able to provide you with the Local lockout pin, as it is uniquely
created at the time of the lockout.
Entering the OAC Lockout PIN
Table 4.4: Entering the OAC Lockout PIN
Step
Action
Result
1.
Go to the system options menu,
located under the Advanced submenu
in the setup menu.
The display will read “ADV: SYSTEM OPTIONS” on
the top line.
2.
Scroll until LL Pin is displayed
3.
Press right once, and edit the four digit
PIN until the lockout PIN is displayed.
4.
Exit the menu by moving the cursor to
the right outside the edit area.
The menu returns to the “ADV:SYSTEMS OPTIONS”
menu. The unit is now in local control mode.
4.2
Returning the Unit to Local Control Mode
Once the unit is in remote control mode, no local controls are available. To
reacquire local control, it is necessary to set the remote control parameter
back to “local”.
Table 4.5: Configuring the Unit for Local Control
Step
Action
Result
1.
Go to the system options menu,
located under the Advanced submenu
in the setup menu.
The display will read “ADV: SYSTEM OPTIONS” on
the top line.
2.
Scroll until halfway down the menu,
where the item “Ctrl. Mode” is shown.
3.
Press right once, and then by using the
up and down arrows, key in the desired
control mode, in this case: “local”.