Installing the Equipment
Reference Guide: evolution 5000 E5780 and E5782 Encoder
Page 2-7
ST.RE.E10135.4
Table 2.1: Supply Cable Wiring Colours
UK
(BS 1363)
EUROPE
(CEE 7/7)
USA
(NEMA 5-15P)
Earth:
Green-and-yellow Green-and-yellow Green
Neutral:
Blue Blue White
Live:
Brown Brown Black
If the colours do not correspond with the coloured markings identifying the terminals in a
locally supplied plug, proceed as in
Table 2.2: Non Standard Supply Cord Wire Colours
Wire Colour (UK)
Action
green-and-yellow
...must be connected to the terminal in the plug which is marked with the letter E or the safety earth
symbol or coloured green or green-and-yellow.
blue
...must be connected to the terminal in the plug which is marked with the letter N or coloured black.
brown
...must be connected to the terminal in the plug which is marked with the letter L or coloured red.
Protective Earth/Technical Earth
WARNINGS...
1.
THIS UNIT MUST BE CORRECTLY EARTHED THROUGH THE MOULDED PLUG SUPPLIED.
IF THE LOCAL MAINS SUPPLY DOES NOT HAVE AN EARTH CONDUCTOR DO NOT
CONNECT THE UNIT. CONTACT CUSTOMER SERVICES FOR ADVICE.
2.
BEFORE CONNECTING THE UNIT TO THE SUPPLY, CHECK THE SUPPLY REQUIREMENTS
IN ANNEX B.
The unit has a Technical earth terminal (marked with ) located at the rear panel (see
and
). Its use is recommended. This is
NOT
a Protective earth for electric
shock protection. The terminal is provided to:
1.
Ensure all equipment chassis fixed within a rack are at the same Technical earth
potential. To do this, connect a wire between the Technical earth terminal and a suitable
point on the rack.
2.
Eliminate the migration of stray charges when connecting between equipment.
WARNING...
IF THE TERMINAL SCREW HAS TO BE REPLACED, USE A M5 X 12mm LONG POZIDRIV
PANHEAD. USING A LONGER SCREW MAY CAUSE A SAFETY HAZARD.
Connecting the Encoder to the A.C. Power Supply
WARNINGS...
1. DO NOT OVERLOAD WALL OUTLETS AND EXTENSION CORDS AS THIS CAN RESULT IN A
RISK OF FIRE OR ELECTRIC SHOCK.
2. AS NO MAINS SWITCH IS FITTED TO THIS UNIT, ENSURE THE LOCAL A.C. POWER SUPPLY
IS SWITCHED OFF BEFORE CONNECTING THE SUPPLY CORD.
3. THE ENCODER IS NOT FITTED WITH AN ON/OFF SWITCH. ENSURE THAT THE SOCKET-
OUTLET IS INSTALLED NEAR THE EQUIPMENT SO THAT IT IS EASILY ACCESSIBLE.