Setting of the Remux Card for Data/PSIP and DVB-Subtitles Input
Page J-4
Reference Guide: evolution 5000 E5780 and E5782 Encoder
ST.RE.E10135.4
By default, the Ancillary page ID for each DVB-Subtitles elementary stream equals the value
of the Composition page ID.
J.2.2
The Setting Sequence
1.
Identifiy the Remux card input which will supply the
DVB-Subtitles
elementary streams
2.
For the selected input, change
Remux input # in mode
to
Off
.
3.
Configure the value of
DVB-Subtitles
(up to four streams are possible).
4.
Configure the descriptors for all the selected
DVB-Subtitles
elementary streams.
5. Finally,
change
Remux input # in mode
to
DVB subt
.
J.3
The DATA Input Mode
J.3.1 Overview
The DATA input mode allows the mapping a set of elementary streams directly to the output of
the Remux card.
The set of elementary streams is defined, for each Remux card input, by a range of PID
values.
NOTES
1. The “DATA” input mode will be available when the syntax is: DVB and ATSC.
2. Any Remux card input can be in DATA mode at any time.
3. The set of the allowed PID values ranges from 0 to 8190.
4. The Encoder will not reference any data streams in its internally generated PSI. If this is required,
switch internal PSI off by setting SI Level to Off
CAUTION…
It is the user’s responsibility to supply PSI on a Remux input.