Alarm List
Reference Guide: evolution 5000 E5780 and E5782 Encoder
Page L-5
ST.RE.E10135.4
Alarm Id
Alarm Name
Alarm Description Level
Source
Module
00000225
No SET_RATE
Messages Received
No Reflex bitrate messages received in the last 2 seconds
Alarm
Video Encoder
00000226
SET_RATE Messages
Expired
PCR time stamp for the Reflex bitrate message received occurs in
the past.
Alarm Video
Encoder
00000280
Module Fault
Applies to the Motherboard modules only. The audio module has
failed to boot.
Alarm
Audio A
00000281
Comms Error
"Not set in normal operation. For use with MEM controller, to force a
new config download as a result of an error."
Alarm
Audio A
00000282
Config Update
The audio module is not responding correctly to the requested
config.
Alarm
Audio A
00000284
Incorrect Parameters
One or more parameters are incorrect.
Alarm
Audio A
00000285
PCR Error
Unable to read the internal PCR count.
Alarm
Audio A
00000286
Silence Timeout Left
The audio level of the left channel was below the silence threshold
longer than the programmed timeout.
Alarm
Audio A
00000287
Silence Timeout Right
The audio level of the right channel was below the silence threshold
longer than the programmed timeout.
Alarm
Audio A
00000288
Level Clipping Left
The audio level of the left channel is above the clipping threshold.
Alarm
Audio A
00000289
Level Clipping Right
The audio level of the right channel is above the clipping threshold.
Alarm
Audio A
00000290
Embedded Source 1
The embedded audio input source is missing.
Alarm
Audio A
00000291
Embedded Source 2
The embedded audio input source is missing.
Alarm
Audio A
00000292
Embedded Source 3
The embedded audio input source is missing.
Alarm
Audio A
00000293
Embedded Source 4
The embedded audio input source is missing.
Alarm
Audio A
00000294
AC-3 Input Invalid
No input stream when the coding is Dolby digital AC-3 pass-thru.
Alarm
Audio A
00000295
No Digital Input
Too many errors on the digital audio input.
Alarm
Audio A
00000296
Mux FIFO Overflow
Error on the internal Mux input. The audio channel will be reset.
Alarm
Audio A
00000297
Duplicate PID
The selected PID value clashes with another.
Alarm
Audio A
00000298
Invalid PID
The selected PID value is out of range.
Alarm
Audio A
00000299
Mux Bitrate too low
The output bitrate is too low. The audio output will be switched off.
Alarm
Audio A
00000300
Audio Un-Calibrated
The analog audio input is not calibrated.
Alarm
Audio A
00000301
Lip Sync Error
The requested delay exceeds the maximum value allowed for the
current coding standard and hardware.
Alarm
Audio A
00000302
Invalid Sampling Rate
The sampling frequency is incompatible with the coding mode Dolby
digital AC-3 pass-thru.
Alarm
Audio A
00000303
ADS Input Invalid
Unable to detect valid MPEG-2/Audio Descriptor Service on input.
Alarm
Audio A
00000304
DTS Input Invalid
Unable to detect a valid DTS Audio stream on input.
Alarm
Audio A
00000305
Wrong Dolby
Standard
Encoder is set to Dolby Digital Plus but the audio input is Dolby
Digital or vice versa
Alarm Audio
A
00000320 Module
Fault
Applies to the Motherboard modules only. The audio module has
failed to boot.
Alarm
Audio B
00000321
Comms Error
"Not set in normal operation. For use with MEM controller, to force a
new config download as a result of an error."
Alarm
Audio B
00000322
Config Update
The audio module is not responding correctly to the requested
config.
Alarm
Audio B
00000324
Incorrect Parameters
One or more parameters are incorrect.
Alarm
Audio B
00000325
PCR Error
Unable to read the internal PCR count.
Alarm
Audio B
00000326
Silence Timeout Left
The audio level of the left channel was below the silence threshold
longer than the programmed timeout.
Alarm
Audio B
00000327
Silence Timeout Right
The audio level of the right channel was below the silence threshold
longer than the programmed timeout.
Alarm
Audio B