D14128.03—JULY 2009
89
Codec C90
System Integrator Guide
Contents
Introduction
Getting Started
Interfaces
About the API
xConfiguration
xCommand
xStatus
Cameras
Appendices
Contact us
xCommand Experimental Audio LocalOutput Unmute
Unmute the local audio output.
Parameters: Required parameters are marked with (
r
):
ConferenceId(
r
): <0..65534>
Example:
xCom mand Experimental Audio LocalOutput Unmute ConferenceID:1
*r AudioLocalOutputUnmuteResult (status=OK):
** end
xCommand Experimental Audio LocalOutput MicrophoneReinforcement Add
For a detailed description of the microphone reinforcement functionality, see Appendix > Microphone
reinforcement section.
Turn on microphone reinforcement on a local output by specifying its output ID. The loudspeaker setting
on this local output must be On. Only one local output can enable microphone reinforcement at a time. All
loudspeakers connected to this local output are in zone 2, and thus play out the microphones in zone 1.
InputConnectors: Choose the pair of microphones to be reinforced, and thus be played out on the speakers in
zone 2. These microphones will be in zone 1.
Gain: Set the gain on the microphones that are reinforced in the range from -53 dB to 15 dB. -54 dB equals
OFF.
EqualizerMode: Determines whether or not the selected equalizer should be enabled.
EqualizerId: Select equalizer [1..8] for the reinforced microphone input signals.
Parameters: Required parameters are marked with (
r
):
OutputId(
r
): <0..65534>
InputConnectors(
r
): <Microphone1_2/Microphone3_4/Microphone5_6/Microphone7_8>
Gain(
r
): <-54..15>
EqualizerMode(
r
): <On/Off>
EqualizerId(
r
): <1..8>
Example:
xCom mand Experimental Audio LocalOutput MicrophoneReinforcement Add OutputId:
6 InputConnectors: Microphone1_2 Gain: 0 EqualizerMode: Off EqualizerId: 1
*r AudioLocalOutputMicrophoneReinforcementAddResult (status=OK):
** end
xCommand Experimental Audio LocalOutput MicrophoneReinforcement Update
For a detailed description of the microphone reinforcement functionality, see Appendix > Microphone
reinforcement section.
Update the gain and equalizer settings of the microphone reinforcement configuration by specifying the ID of
the local output.
Gain: Set the gain on the microphones that are reinforced in the range from -53 dB to 15 dB. -54 dB equals
OFF.
EqualizerMode: Determines whether or not the selected equalizer should be enabled.
EqualizerId: Select equalizer [1..8] for the reinforced microphone input signals.
Parameters: Required parameters are marked with (
r
):
OutputId(
r
): <0..65534>
Gain(
r
): <-54..15>
EqualizerMode(
r
): <On/Off>
EqualizerId(
r
): <1..8>
Example:
xCom mand Experimental Audio LocalOutput MicrophoneReinforcement Update
OutputId: 6 Gain: -3 EqualizerMode: Off EqualizerId: 1
*r AudioLocalOutputMicrophoneReinforcementUpdateResult (status=OK):
** end
xCommand Experimental Audio LocalOutput MicrophoneReinforcement Remove
For a detailed description of the microphone reinforcement functionality, see Appendix > Microphone
reinforcement section.
Turn off microphone reinforcement on the local output given by the output ID.
Parameters: Required parameters are marked with (
r
):
OutputId(
r
): <0..65534>
Example:
xCom mand Experimental Audio LocalOutput MicrophoneReinforcement Remove
OutputId: 6
*r AudioLocalOutputMicrophoneReinforcementRemoveResult (status=OK):
** end
The Experimental menu
The Experimental commands can be used ‘as is’ and will not be further documented.
NOTE!
The Experimental commands WILL change.
We recommend you visit the TANDBERG web site regularly for updated versions of the manual.
Go to:
Contents
Introduction
Getting started
Interfaces
About the API
xConfiguration
xCommand
xStatus
Cameras
Appendices
Contact us
xCommand