172
OPTIONS
Travel Alarm
An alarm is sounded when the machine
travels and stops when traveling is stopped.
If the alarm does not sound when the
machine travels, the fuse may be blown.
Inspect the fuse.
WARNING
If the fuse which has just been replaced
should blow again, there is a problem in
the electrical system. This could cause
fires. Contact a Takeuchi dealer.
1. Park the machine in a safe place.
2. Set the starter switch to “OFF”.
3. Open the cover (1).
4. Inspect for blown fuse.
5. If a fuse is blown, replace it with a spare
fuse of the same capacity.
E4J007
Normal
Blown
Fuse Layout and Circuits Protected
Capacity Protected circuit
10A
Reserve
20A
Stop solenoid
10A
Lever lock
10A
Second travel speed
15A
Lights
10A
Horn
15A
Instrument panel
Feed pump
15A
Radio
Heater
20A
Cigarette lighter
Wiper (cab)
10A
External power socket
Travel alarm
10A
Interior light (cab)
Capacity Protected circuit
*: There are spare fuses (10A, 15A and 20A)
at the center of the fuse box.