Operation and setting of M-axis (bobbin)
103
Chapter 5
1
2
3
4
5
6
7
8
9
10
11
12
RR05
1-4.
To return M-axis to the origin manually (Manual M-axis Power-ON Restore)
When detected angle of bobbin is misaligned, this operation returns the bobbin to the previous angle before
misalignment by manual operation.
Use this function in such a case as when M-axis is misaligned due to turning of the bobbin by hand at power
turned OFF. It is effective only when misaligned angle against the correct angle is less than 180°.
1-4-1.
Explanation on the screen
1-4-2.
How to operate
The following example is for executing manual M-axis power-on restore.
(1)
To open screen
(2)
To select power resume
(3)
To execute
When performing this operation, do not put your hands etc. near the needle. Rotating
bobbin could injure you.
F4
1-------/Manual M-axis Power-ON Restore
Origin Return
Power resume
Return M-axis to the original position
: Not to execute
: To execute
!
CAUTION
1 Manual M-axis Power-ON Restore
Summary of Contents for TLMX Series
Page 23: ...Inspection before starting work 8 Chapter 1 ...
Page 59: ...Attachment 44 Chapter 2 ...
Page 113: ...Embroidery starts 98 Chapter 4 ...
Page 145: ...Operation and setting for embroidering 130 Chapter 5 2 Select the value 3 RR05 ...
Page 209: ...Other functions that must be remembered 194 Chapter 6 ...
Page 231: ...To resister frame position 216 Chapter 7 ...