Supplemental documentation
15-7
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
2.
Ambient noise level
The ambient noise level of the machine is less than 85 dB. Measuring
conditions are as follows:
1.
Measuring ambience (refer to the illustration
shown right)
2.
Measuring position
Measured at B and C
*Higher value is adopted.
Height: 1.6 m from the floor
3.
Operating condition of the machine
Fabric is stretched on the border frame and satin stitch
sewing of stitch length 4 mm is executed.
4.
R. P. M.
The maximum number of revolutions of the machine
5.
Measuring tool
Conformity to IEC61672-1: 2002 Class 1
3.
Power supply specifications
Since power spec. of the machine is specified clearly as shown below,
use the machine under these conditions.
VOLTAGE, ALLOWABLE VOLTAGE RANGE:
/-10% of the rated voltage
POWER CONSUMPTION (MAX):
140W/180VA
FREQUENCY:
50/60Hz
INSULATION RESISTANCE:
10M ohms or more (at 500 V megger)
WARNING
Since there is a danger of electric shock due to leak current,be sure to ground the earth cable of the
machine. In addition,degree of grounding should be type D or higher (grounding resistance 100
ohms or less).
5 m or more
5 m or more
5 m or more
1.0m
1.5m
A
C
B
A: Position of
Wall
5 m or more
needle location
!
JZ07
Summary of Contents for TCMX 601
Page 1: ...USER S MANUAL TCMX 601 M XL01 E 2006 07 TCMX 601 ...
Page 18: ...Name of each part and function 2 7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ...
Page 19: ...2 8 Name of each part and function ...
Page 41: ...4 14 Basic operation ...
Page 65: ...6 8 Convenient functions ...
Page 105: ...11 12 Software installation and necessary ...
Page 119: ...14 6 Maintenance ...
Page 129: ...15 10 Supplemental documentation ...