264
Receiver Fault Finding
TM8100/TM8200 Service Manual
© Tait Electronics Limited
November 2007
Task 16 —
RSSI Muting
Selected
With RSSI muting selected, check the RSSI mute settings.
1.
In the calibration application open the
“Deviation/Squelch”
page and
click the
“Squelch and Signaling Thresholds”
tab.
2.
Check that the values in the
“Opening Pt”
fields and the
“Hysteresis”
fields under the
“Squelch Thresholds”
label are what the Customer
expects.
3.
If the calibration values are as expected, go to
Task 10
and check the
RSSI calibration. If they are not, go to
Step 4
.
4.
Adjust the values in the
“Opening Pt”
and
“Hysteresis”
fields. Program
the radio with the new values.
5.
Check if the mute fault has been removed. If it has, go to
“Final
Tasks” on page 163
. If it has not, go to
Task 10
and check the RSSI
calibration.
Figure 10.5
TCXO circuitry under the
CDC TOP
can (top side)
Summary of Contents for TM8100 mobiles
Page 1: ...TM8100 mobiles TM8200 mobiles Service Manual MMA 00005 05 Issue 5 November 2007...
Page 10: ...10 TM8100 TM8200 Service Manual Tait Electronics Limited November 2007...
Page 12: ...12 TM8100 TM8200 Service Manual Tait Electronics Limited November 2007...
Page 20: ...20 Introduction TM8100 TM8200 Service Manual Tait Electronics Limited November 2007...
Page 64: ...64 Description TM8100 TM8200 Service Manual Tait Electronics Limited November 2007...
Page 106: ...106 TM8100 TM8200 Service Manual Tait Electronics Limited November 2007...
Page 134: ...134 General Information TM8100 TM8200 Service Manual Tait Electronics Limited November 2007...
Page 168: ...168 Servicing Procedures TM8100 TM8200 Service Manual Tait Electronics Limited November 2007...
Page 464: ...464 Spare Parts TM8100 TM8200 Service Manual Tait Electronics Limited November 2007...