228
Frequency Synthesizer Fault Finding
TM8100/TM8200 Service Manual
© Tait Electronics Limited
November 2007
Task 29 —
Repair PLL feedback
If both the maximum and minimum VCO frequencies are correct, then the
PLL feedback is suspect.
1.
Resolder
R542
in position (see
Figure 9.14
).
2.
Remove the
VCO
BOT
can.
3.
Replace the components
L510
(see
Figure 9.15
) and
IC503
(see
Figure 9.14
).
Note
On A4 band radios there is no L510. Replace L5010 instead.
4.
Confirm that the fault in the radio has been removed. If it has, go to
“Final Tasks” on page 163
. If it has not, replace the board and go to
“Final Tasks” on page 163
.
Summary of Contents for TM8100 mobiles