TM8100/TM8200 Service Manual
Power Supply Fault Finding
173
© Tait Electronics Limited
November 2007
2.
Disconnect the 13.8V supply at the power connector. Remove
R199
(see
Figure 7.1
). Reconnect the 13.8V supply.
3.
With the probe of the multimeter on the
3
V
3
test point
, press the
ON
/
OFF
key. If the voltage is now 3.3 ± 0.1V, the digital board is faulty;
replace the board and go to
“Final Tasks” on page 163
. If the voltage
is still not correct, go to
Step 4
.
4.
If the digital board is functional, the fault is on the main board.
Replace
R199
. Disconnect the 13.8V supply. Use the multimeter to
measure the resistance between the
3
V
3
test point
and ground.
If there is a short circuit, continue with
Step 5
. If there is no short
circuit (but the voltage is wrong), go to
Step 7
.
5.
Search for shorts to ground in the components
C603
,
C612
,
C613
,
C618
,
D606
of the SMPS circuitry (see
Figure 7.1
) as well as in the
CODEC and interface circuitry. Repair any fault and repeat the
resistance measurement of
Step 4
to confirm the removal of the fault.
If there is no fault, go to
Step 6
. If the fault remains, the repair failed;
replace the board and go to
“Final Tasks” on page 163
.
6.
Reconnect the 13.8V supply. Press the
ON
/
OFF
key. If the radio powers
up, return to
“Initial Tasks” on page 155
. If the radio fails to power
up, disconnect the 13.8V supply and go to
Step 7
.
7.
Measure the resistance of
L601
(see
Figure 7.1
). The resistance
should be virtually zero. If it is, go to
Step 8
. If it is not, replace L601.
Reconnect the 13.8V supply and press the
ON
/
OFF
key. If the radio
powers up, return to
“Initial Tasks” on page 155
. If the radio fails to
power up, disconnect the 13.8V supply and go to
Step 8
.
8.
Remove the
CDC BOT
can. Remove
IC603
(3.0V regulator) and
IC604
(2.5V regulator) (see
Figure 7.3
). Reconnect the 13.8V
supply and press the
ON
/
OFF
key. If the 3.3V supply is restored, go to
Task 3
to check each regulator (3.0V and 2.5V) in turn. If the 3.3V
supply is not restored, continue with
Step 9
.
9.
Suspect
IC602
. Disconnect the 13.8V supply. Replace IC602 with a
spare (see
Figure 7.1
). Resolder
IC603
and
IC604
in position
(see
Figure 7.3
). Reconnect the 13.8V supply and press the
ON
/
OFF
key. If the radio powers up, return to
“Initial Tasks” on page 155
.
If the radio fails to power up, the repair failed; replace the board and
go to
“Final Tasks” on page 163
.
Summary of Contents for TM8100 mobiles
Page 1: ...TM8100 mobiles TM8200 mobiles Service Manual MMA 00005 05 Issue 5 November 2007...
Page 10: ...10 TM8100 TM8200 Service Manual Tait Electronics Limited November 2007...
Page 12: ...12 TM8100 TM8200 Service Manual Tait Electronics Limited November 2007...
Page 20: ...20 Introduction TM8100 TM8200 Service Manual Tait Electronics Limited November 2007...
Page 64: ...64 Description TM8100 TM8200 Service Manual Tait Electronics Limited November 2007...
Page 106: ...106 TM8100 TM8200 Service Manual Tait Electronics Limited November 2007...
Page 134: ...134 General Information TM8100 TM8200 Service Manual Tait Electronics Limited November 2007...
Page 168: ...168 Servicing Procedures TM8100 TM8200 Service Manual Tait Electronics Limited November 2007...
Page 464: ...464 Spare Parts TM8100 TM8200 Service Manual Tait Electronics Limited November 2007...