Alarms
CP560 DVB-T2 Gateway User’s Manual Rev. 2.2 (3686)
ID: um_t2gateway
Table G.3.d
Alarms
Alarm ID Text
Def. severity Details
507
Auto switching disabled
Warning
Description:
Enabled when auto switching is turned off.
Type:
Relay Switch (
Type ID
= 19)
Clear event:
Yes
Subid2:
Relay switch controller ID
508
Auto switch performed
Filtered
Description:
Automatic switch is performed. This alarm will stay on until it is manually
confirmed by the operator (see chapter on switch config).
Type:
Relay Switch (
Type ID
= 19)
Clear event:
Yes
Subid2:
Relay switch controller ID
517
Alarm log cleared
Notification
Description:
Alarm log was cleared, user in details
Type:
System (
Type ID
= 13)
Clear event:
No
518
System is starting up
Critical
Description:
This alarm is set when the system is starting. Once booted correctly, the
alarm is cleared.
Type:
System (
Type ID
= 13)
Clear event:
Yes
519
Forced reset initiated
Notification
Description:
A reset of the device was forced by the operator.
Type:
System (
Type ID
= 13)
Clear event:
No
520
SW loading in progress
Notification
Description:
Loading of an embedded SW image is in progress
Type:
System (
Type ID
= 13)
Clear event:
Yes
521
New SW pending
Notification
Description:
A SW image has been successfully loaded, but manual reboot is needed for
SW to be activated.
Type:
System (
Type ID
= 13)
Clear event:
Yes
524
Simultaneous users
Notification
Description:
Multiple users with administrator or operator access level are logged in.
Type:
System (
Type ID
= 13)
Clear event:
Yes
526
Action performed
Notification
Description:
Action performed by user. Used to log generic important events, see details
field on each alarm event for additional information.
Type:
System (
Type ID
= 13)
Clear event:
No
527
New SW license pending
Notification
Description:
New SW licenses have been loaded but requires a re-boot to be activated.
Type:
System (
Type ID
= 13)
Clear event:
Yes
528
New SW license installed
Notification
Description:
New SW licenses have been loaded and installed without requiring reboot.
Type:
System (
Type ID
= 13)
Clear event:
No
529
Timesync error
Major
Description:
Not able to synchronize internal time to external time references.
Type:
System (
Type ID
= 13)
Clear event:
Yes
Summary of Contents for CP560
Page 2: ......
Page 10: ...10 CP560 DVB T2 Gateway User s Manual Rev 2 2 3686 ID um_t2gateway...
Page 16: ...16 CP560 DVB T2 Gateway User s Manual Rev 2 2 3686 ID um_t2gateway...
Page 22: ...22 CP560 DVB T2 Gateway User s Manual Rev 2 2 3686 ID um_t2gateway...
Page 28: ...28 CP560 DVB T2 Gateway User s Manual Rev 2 2 3686 ID um_t2gateway...
Page 34: ...34 CP560 DVB T2 Gateway User s Manual Rev 2 2 3686 ID um_t2gateway...
Page 142: ...142 CP560 DVB T2 Gateway User s Manual Rev 2 2 3686 ID um_t2gateway...
Page 150: ...150 CP560 DVB T2 Gateway User s Manual Rev 2 2 3686 ID um_t2gateway...
Page 156: ...156 CP560 DVB T2 Gateway User s Manual Rev 2 2 3686 ID um_t2gateway...
Page 166: ...166 CP560 DVB T2 Gateway User s Manual Rev 2 2 3686 ID um_t2gateway...
Page 172: ...172 CP560 DVB T2 Gateway User s Manual Rev 2 2 3686 ID um_t2gateway...
Page 182: ...182 CP560 DVB T2 Gateway User s Manual Rev 2 2 3686 ID um_t2gateway...