![T-Drill F-400 Instruction Manual Download Page 48](http://html1.mh-extra.com/html/t-drill/f-400/f-400_instruction-manual_3075621048.webp)
INSTRUCTION MANUAL
48
6.5 ADJUSTMENT OF FORMING DEVICE
L
DANGER! Before closing the clamping jaws, make sure that they can
move freely - the jaws might crush your hands!
1. Clamp the pipe.
2. Set the “Start Pos.” to zero (0.0mm) on the display (See previous chapter).
3. Drive the carriage forward until the tool almost reaches the pipe end with switches 13
and 14
. Both switches have to be pressed simultaneously.
4. Press power off, open the protective hood and ensure that the forming pin can go into
the pipe without collision.
If not, adjust the forming pin position:
- Loosen the lock nuts (4 pcs) of slide.
Locking nuts of the slide
- Adjust the slide position by means of adjustment screw so that there is a clearance of
abt. 5 mm between the pipe and the pin.
- After adjusting the slide position, tighten the lock nuts. (Tightening torque 70 Nm)
Adjustment screw of the slide and the clearance between pipe wall and forming pin.