IPC/RSL8xxx-XxxxE: user documentation
DOC/IPC_RSL8-E; V1.9
© Syslogic Datentechnik AG, Switzerland, http://www.syslogic.com
69
/
80
6
Service
6.1.
Replaceable Parts
This RSL8 system contains the following replaceable parts:
-
CFast flash card
-
Litium battery
-
Main fuse
To replace the flash card power off the system and remove the service cover. After having
unlocked the clip, the flash card may be removed. When inserting a new flash card be sure that
it is fully compliant with the CFast standard. Syslogic highly recommends CFast flash cards
specified for industrial use by the card manufacturer. Check temperature range and durability
to comply with your requirements.
To replace the battery power off the system and remove the service cover. Pull out the batter<y
carefully.
Replacement battery must be one of the following types:
-
Renata CR2450N (3V, 540mAh)
-
Renata CR2477N (3V, 950mAh)
Because the self-discharge of all Lithium Batteries increases rapidly at high temperatures the
battery life time decreases by a great amount. To prevent battery leakage scheduled
service/replacement is recommended. Please contact the battery manufacturer for further
details and calculation assistance for battery life time calculation.
The main fuse protects the system against destruction in case of high energy distortions on the
power line. For replacement, the system must be opened in a ESD protected environment. Only
an entitled instructed person is allowed for this operation. Replacement fuse type is Littlefuse
0452004.MRL (4A slow-blow).
Safety warnings and installation guidelines must be followed according to paragraphs 1.6, 1.8
and 5.
Fig. 17 Service parts replacement