IPC/RSL8xxx-XxxxE: user documentation
DOC/IPC_RSL8-E; V1.9
© Syslogic Datentechnik AG, Switzerland, http://www.syslogic.com
23
/
80
The processor module on the RSL8 board offers a JTAG interface for factory operations on
the internal header P11. These pins
must not
be connected by the user.
Pin Number
Signal
Remarks
1
TCK (do not connect)
2
TDO (do not connect)
3
TDI (do not connect)
4
TMS (do not connect)
5
TRST (do not connect)
6
GND (do not connect)
Tab. 5 Factory Programming Header P11 (1x6 pin)
The programmable logic device on the RSL8 board is factory programmed using some pins of
the internal header P12. These pins
must not
be connected by the user.
Pin Number
Signal
Remarks
1
TCK (do not connect)
2
TDO (do not connect)
3
TMS (do not connect)
4
TDI (do not connect)
5
VCC (do not connect)
3.3V
6
GND (do not connect)
Tab. 6 Factory Programming Header P12 (1x4 pin)
The power management controller on the RSL8 board is factory programmed using the internal
header P17. This header
must not
be connected by the user.
Pin Number
Signal
Remarks
1
VPP/MCLR# (do not connect)
PICkit3 pin 1
2
VCC (do not connect)
PICkit3 pin 2
3
GND (do not connect)
PICkit3 pin 3
4
PGD (ICSPDAT, do not connect)
PICkit3 pin 4
5
PGC (ICSPCLK, do not connect)
PICkit3 pin 5
6
PGM LVP (SCL, do not connect)
PICkit3 pin 6
7
-- (SDA, do not connect)
--
Tab. 7 Factory Programming Header P17 (1x7 pin)