Technical Data
7.1.
Electrical Data
Important Note
Do not operate the RSL8 system outside of the recommended operating conditions.
Otherwise lifetime and performance will degrade. Operating the board outside of the
absolute maximum ratings may damage the hardware.
Absolute Maximum Ratings (over free-air temperature range)
Parameter
Symbol
min
nom
max Unit
general parameters
power supply voltage
Vcc
-0.5
30.0 Vdc
power supply voltage (<1s)
Vcc
-0.5
33.6 Vdc
isolations
power supply to chassis (AC, 60s, 500m a.s.l.,
Ta=25°C)
500
Vrms
power supply to logic (AC, 60s, 500m a.s.l.,
Ta=25°C)
500
Vrms
isolation Ethernet to chassis (AC, 60s, 500m a.s.l.,
Ta=25°C)
500
Vrms
isolation Ethernet to logic (AC, 60s, 500m a.s.l.,
Ta=25°C)
500
Vrms
creepage distances:
power supply to chassis/logic
1.3
mm
Ethernet to chassis/logic
1.0
mm
temperature range
operating free-air temperature (Ambient)
Ta
-40
70 °C
storage temperature range
1
Tst
-40
85 °C
Tab. 35 General Absolute Maximum Ratings
1
Due to the large effect of self-discharge at high temperature of the Lithium Battery it is
recommended to store the device at 25°C.