Operation
6.2 Operation via SYR App
As an alternative to operating the device directly, you can also perform the basic
settings via your smartphone. Simply download the SYR App to your smartphone
or use your web browser (http://syrconnect.de) and follow the user guidance
Fig. 21: Control panel of SYR App
6.3 Emergency shut-off function
The emergency shut-off function serves the purpose of manual isolation of the
installation during refill operations in case of a power failure (when no batteries
are inserted or they are empty)
The emergency shut-off function is located underneath the control unit.
►
Disconnect all the lateral connectors and the 7-pole adapter (1).
►
Remove the two insulating shells on the sides for manual isolation.
The key for manual isolation is located on the inside of the left insulating shell.
►
Remove the control unit‘s clamp (2) so that you can lift up the control unit (3).
Attention!
Potential material damage through improper removal of the con-
trol unit!
►
Observe the correct cable routing!
30