Operation
6.1.3 Adjustment of the limit value for volume-based leakage
Menu settings are described for volume-based leakage by way of example.
Please proceed as follows:
►
Press
.
The first line of the display reads “Parameter/Info”.
►
Press
again
The first line of the display reads “Expert setting”.
Underneath “Limit value volume-based leakage Off.
►
By pressing
and
you can modify the value. Settings can be adjusted
in 10 l increments.
►
Confirm the setting by pressing
.
6.1.4 Choice and exchange of catridge
If the fully automatic filling system for heating installations is equipped with a water
conditioning cartridge, the latter has to be pre-set.
Basiseinstellungen
BASISEINSTELLUNG
BASISEINSTELLUNG
BASISEINSTELLUNG
BASISEINSTELLUNG
BASISEINSTELLUNG
Füllbetrieb inklusive
Bitte messen Sie die
Wasserbehandlung
Kartuschentyp
Kartuschengröße
Kartuschenwechsel
Rohwasserhärte
JA
HVE Plus
14 Liter
JA
Bestätigen: ENTER
Fig. 17:
Menu for choice of water conditioning cartridge (basic settings)
►
Go to basic menu -> Filling mode incl. water conditioning and select
YES
.
►
Choose the cartridge type (HWE, HVE,
HVE Plus
) and size (4, 7,
14
or 30
liters).
►
Select cartridge exchange
YES
.
►
Draw raw water at arbitrary draw-off point upstream of the heating installation
and measure the water hardness degree with a hardness measuring device.
►
Enter the measured value of raw water hardness in the menu.
BASISEINSTELLUNG
BASISEINSTELLUNG
BASISEINSTELLUNG
BASISEINSTELLUNG
BASISEINSTELLUNG
t
ä
ti
z
a
p
a
K
e
t
e
n
h
c
e
r
r
E
e
i
d
e
i
S
n
e
s
s
e
m
e
tt
i
B
Rohwasserhärte
Weichwasserhärte
Weichwasserhärte
1400 L
Solldruck
20 °dH
Bestätigen: ENTER
4 °dH
Bestätigen: ENTER
2,0 bar
Fig. 18:
Menu for choice of water conditioning cartridge (basic settings)
►
Enter the desired value for soft water hardness in the menu.
The control unit calculates the capacity of the water conditioning cartridge based
on the entered values.
►
Enter the target pressure.
Note:
All other parameters are
set in similar form.
Note:
The settings for “raw
water
hardness”,
“cartridge exchange” and
“soft water hardness”
have to be renewed after
each cartridge exchange!
Note:
This query is void in
case you use HVE or
HVE Plus cartridges!
28