Dismounting and disposal
Error
Cause
Troubleshooting
AB
No minimum pressure increase
During the filling, no minimum pressu-
re increase occured wihin a determi-
ned period of time after the start of the
filling process.
- Press to open the isolating
valve and continue refill
process, check whether the
inlet pressure is sufficient and
the flow sensor emits impulses
(yellow LED)
AC
Error pressure sensor
The pressure sensor emits no signal.
- Make sure that batteries are
inserted and connection to the
power supply is provided.
- Contact the SYR service.
M1
Cartridge fill level 1...10 %
The cartridge‘s capacity is almost
depleted .
- Provide for exchange granules
in due time, fill the cartridge or
replace the empty cartridge by a
new one .
M2
Batteries almost spent
The batteries‘ capacity is almost
spent .
- Replace the batteries.
9
Dismounting and disposal
9.1 Dismounting
If the fully automatic filling system works no more, it has to be dismounted and
disposed of in a environmentally friendly way.
►
Remove the power adapter and the network cable.
►
Dismount the device with the connection flange.
9.2 Disposal
If no agreements have been made for return or disposal, have the dismantled
components recycled:
►
Have metals scrapped
►
Have synthetic parts recycled
36