Section IV
Multiple Unit Configuration
006-0006885 08/14/18
Rev H
30 of 48
MINV-4000-1U-28 Guide www.synqor.com
Parallel Configurations of the AC OUTPUTS: Up to 32 Units
The “F” or “R” options allow up to 32 MINV units to be placed in parallel in Single-Phase, Split-Phase
and 3-Phase configurations. The “R” option adds a single pole, electronic breaker to the hot wire
of the AC OUTPUT. This breaker allows for fault-tolerant, glitch-free operation of up to 32 MINV
units in a multi-unit system. Single phase, Split-Phase , and 3-Phase systems can be formed. These
systems can be N+1 or N+M redundant on each phase.
The figures below show the different system configurations that can be formed with “F” or “R”
option units. Each system requires its own unique CONFIGURATION cable. Contact the SynQor
factory to purchase system specific configuration cables. Note that configuration cables for two
unit and three unit Single-Phase systems are offered as standard products. See the previous pages
for part numbers.