Installation and connections
Page 22/55
SYCLOPE TERE’O Touch XL
®
Installation, starting, and programming instructions
12)
Remote control input or flow switch connection
SYCLOPE
TERE’O Touch
®
controller has a remote-control input or dry contact flow switch control that
performs a stop function of the regulators.
For safety reasons, it’s imperative to enslve your
SYCLOPE TERE’O Touch
®
to contact with the
filter engine or a flow detection system to avoid overdose incidents.
a)
Version with contact control all or nothing:
In the case of an all or nothing contact system (controlled by the filter motor or a flow sensor), the
following electrical diagram must be made.
Preferably use a two-strand cable.
Wire a strand on
Aux (sw) (4)
.
Wire the other strand on
Aux (-) (5).
Tighten the cable gland to seal.
Your
SYCLOPE
TERE’O Touch
®
has a software configuration of the direction of contact.
You can use either a NO or NC contact and select the type by programming.
b)
Version with NPN inductive detector:
If an inductive type detector is used, connect it as follows:
Remove the protective sheath.
Strip the wires on 7mm.
Pass the cable through the cable gland.
Connect the brown power strand to
Vref + (10).
Connect the blue power strand to
Com - (11).
Connect the black contact strand to
IN2 - (9)
Tighten the cable gland to seal.
Contact