Installation and connections
Page 15/55
SYCLOPE TERE’O Touch XL
®
Installation, starting, and programming instructions
5)
Electrical connection
Electrical installations must be carried out in accordance with the standards in force and by
authorized personnel!
A 30-mA differential circuit breaker must be installed!
A 10A circuit breaker must be installed near the device and easily accessible in order to cut the
primary supply. It must be marked as the cut-off circuit of the device.
Before making the connections, cut off the power supplies!
Preferably use single-strand cables
Otherwise, it is essential to use a crimped cable ends to ensure that no strand can come into
contact with neighbouring cables!
Secure the wire connections on the terminal blocks using a cable tie.
SYCLOPE TERE’O Touch
®
must be slaved to the filtration of the swimming pool using digital
input.
Internal protection:
SYCLOPE ODI Touch
®
is protected by one resettable fuse 160 mA and by a varistor against
overvoltage of 275V.
The self-powered power relay outputs
P3
and
P4
are protected by a glass fuse, 5x20mm of
3.15A 250V.
Reference
Name
FUS1016
Glass fuse time delay 3,15A 5x20
If the fuse is destroyed, check that the card isn’t burnt. If this is the case, imperatively change
the complete card.
If the varistor is destroyed, please return the device to our technical support for expertise.
6)
Changing the internal fuse of P3 and P4 outputs
Cut off the power supply, before changing the fuse!
Always use a fuse identical to the original one. Don’t replace with a higher intensity!