52
Fault
Cause
Remedy
Water flows from hot
tap but has reduced
flow from cold
Cold water pipe kinked preventing flow
Blockage in cold pipe line
Cold tap not connected
Cold tap failed or blocked
Check and re-route if necessary
Disconnect pipes after 1st connector
and check up to tap
Refer to installation instructions
Disconnect and inspect
Reduced flow from
both hot and cold taps
Battery condition low causing pump to
run slowly
If new taps have been fitted they may be
restricting flow
Pump needs servicing
Partially blocked pump filter or in-line
filter, if fitted
Pump outlet pipe kinked restricting flow
Water leak
Check battery state of charge, refer to
electrical supply note
Disconnect and check that they have at
least 1/4” (6.3mm) bore
Refer to pump servicing instructions
Dismantle and clean if necessary
Check and re-route if necessary
Check all water connections
Reduced flow from
either tap
Pipe kinking restricting flow
Bore size difference in taps
Check and re-route if necessary
Use taps of equal bore size
If pump motor runs
steadily and will not
stop
Battery voltage may be too low (below
10.5 volts)
Check that there is water in the
container
Adjust switch and/or re-charge battery.
Check all connections in pipework
WATER SYSTEM FAULT FINDING
Water
C
ONNEC
TIN
G SER
V
ICE
S
Summary of Contents for Select 122 2020
Page 2: ......
Page 3: ......
Page 4: ......
Page 5: ......
Page 6: ......
Page 7: ......
Page 11: ...10...
Page 31: ...30...
Page 32: ...31 EN RO U T E EN ROUTE Fix Go tyre repair kit 32 Cruise Control 34 Parking Sensors 34...
Page 41: ...40...
Page 42: ...41 A RRI VAL AT SI T E ARRIVAL AT SITE Positioning the motorhome 42...
Page 65: ...64...
Page 130: ...129 M O T O RH O ME C ARE Select 164 rear bed BED MAKE UP...
Page 131: ...130...
Page 139: ...138 JACKING POINTS Jacking Point Van Conversion T EC H NIC AL INF O RM AT IO N...
Page 145: ...144 T EC H NIC AL INF O RM AT IO N...