Service
[ S ] 56
Error Correction
Device can't be switched on
The freeAir 100 must be installed flush with the wall box. Clean
the wall box and tap the front plate of the device to assure a tight
fit.In case the device still does not turn on wait several minutes
before switching the device back on.
Blue LEDs blinking
(continuously)
Service- or Dehumidifying operation is active.
Service operation is activated by pushing and holding the
-
Button while the device is switched on. This can happen by
accident or because of a mechanical jamming.
Uninstall the front cover and free the
-Button.
Leave Service operation by switching the device off and back
on.
DIP Switches
Check to see whether a 2
nd
Room Extract connection had been
selected even though the device is not equipped with one (no 4
th
air flap and seal present).
Also check to see whether 1
st
room extract is deselected even
though the 2
nd
Room Extract is not set to 100 m³/h?