Installation
– Bare Brickwork Set
32
[ I ]
Condensate Drain
– PVC-Hose
If, for example, you can arrange the condensate hose between the bricks and the exterior
insulation or in a wall slot, it is common practice for a family house to use a PVC fabric hose.
One possibility is to let the condensate seep at the end at a suitable place.
Hints
• The PCV fabric hose has no explicit approval for this application.
However, the use has proven itself and can be described as state of the art.
• In case of possible icing of the hose, the condensate will be discharged via the outside
hood.
• Protect the hose from damage by laying it in a 25 mm insulating pipe.
Connect the PVC fabric hose securely.
VDIE.0001: Condensate hose, PVC fabric 9/15mm;
VDIE.0002: Connector with clamps
Condensate Drain - Pipe DN32
In apartment buildings, the direct conncetion to a DN32 manifold
is ideal.
Install them frost-free, ensure the roof ventilation and provide a
siphon as an odor trap prior to discharge into the sewage pipe.
VDMI.0001: Adaptor condensate hose
DN32
Summary of Contents for bluMartin freeAir 100
Page 1: ...Manual G General O Operation I Installation S Service ...
Page 20: ...Installation Bare Brickwork Set 18 I Drawings ...
Page 21: ...Installation Bare Brickwork Set 19 I ...
Page 23: ...Installation Bare Brickwork Set 21 I ...
Page 24: ...Installation Bare Brickwork Set 22 I ...
Page 25: ...Installation Bare Brickwork Set 23 I ...
Page 26: ...Installation Bare Brickwork Set 24 I ...
Page 27: ...Installation Bare Brickwork Set 25 I ...
Page 28: ...Installation Bare Brickwork Set 26 I ...
Page 59: ...Service S 57 For troubleshooting visit the website www bluMartin de freeair support ...