Installation
– Bare Brickwork Set
15
[ I ]
Notes
• The freeAir 100 compensates for air stream resistance, due to connected conduit or dirty
filter, by increasing fan speed.
• Therefore supply and exhaust air stream remain constant and balanced.
• “Dirty Filter” error will be indicated once maximum fan speed is reached.
• Longer supply ducting will result in a change in balance between the air flow of the 1
st
and
2
nd
room in favor of the 1
st
room (normal 1 : 1).
2.
Open the appropriate passage and attach the appropriate
ductings or connectors by taking care to use an O-ring or
sealant.
Note
In case of the bare brickwork set with BOX, just remove
the plugs,
for the bare brickwork set without BOX the openings have
to be cut.
3.
Use the included adapter, if you wish to connect another
Round-Flex 75 mm to the 2
nd
room exhaust adapter.
Note
For the bare brickwork set with BOX, this adapter must be
separated.
In case of the bare brickwork set without BOX,
a fourth Round-Flex-Duct can be added using a Flat-Flex-
Round-Flex-Adapter.
Summary of Contents for bluMartin freeAir 100
Page 1: ...Manual G General O Operation I Installation S Service ...
Page 20: ...Installation Bare Brickwork Set 18 I Drawings ...
Page 21: ...Installation Bare Brickwork Set 19 I ...
Page 23: ...Installation Bare Brickwork Set 21 I ...
Page 24: ...Installation Bare Brickwork Set 22 I ...
Page 25: ...Installation Bare Brickwork Set 23 I ...
Page 26: ...Installation Bare Brickwork Set 24 I ...
Page 27: ...Installation Bare Brickwork Set 25 I ...
Page 28: ...Installation Bare Brickwork Set 26 I ...
Page 59: ...Service S 57 For troubleshooting visit the website www bluMartin de freeair support ...