SuperiorFireplaces.us.com
126871-01B
23
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Fireplace
1. Turn control knob clockwise
to the
OFF position.
2. Turn off all electric power to the appliance
if service is to be performed.
3. Close equipment shutoff valve
(see
Fig-
ure 25, Page 20
).
THERMOSTAT
CONTROL OPERATION
The thermostatic control used on this fi replace
differs from standard thermostats. Standard
thermostats simply turn on and off the burner.
The thermostat used on this fi replace senses the
room temperature. The thermostat adjusts the
amount of gas fl ow to the burner. This increases
or decreases the burner fl ame height. At times
the room may exceed the set temperature. If so,
the burner will shut off. The burner will cycle back
on when room temperature drops below the set
temperature.
The control knob can be set to any heat level
between HI and LO.
NOTE
: The thermostat sensing bulb mea-
sures the temperature of air near the fi replace
cabinet. This may not always agree with
room temperature (depending on housing
construction, installation location, room size,
open air temperatures, etc.). Frequent use of
your fi replace will let you determine your own
comfort levels.
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 5 under
Lighting
Instructions
,
Page 22
.
2. With control knob pressed in, strike match.
Hold match to pilot until pilot lights.
3. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Now follow step 8
under
Lighting Instructions
,
Page 22
.
OPERATING
BLOWER
This blower has three settings: ON, OFF, and
AUTO. In the ON position, blower will operate
constantly. In the OFF position, blower will not
operate. In the AUTO position, blower will start
when thermostat senses a suffi cient increase
in fi rebox temperature.
NOTE
: Your fi replace and thermostat blower
will not turn on and off at the same time. The
fi replace may run for several minutes before
blower turns on. After heater modulates to
pilot position, blower will continue to run.
Blower will shut off after fi rebox temperature
decreases.
NOTE
: It is safe to operate fi replace with
blower turned off. However, blower helps
distribute heated air from fi replace.
OPERATION
Continued
OFF
ON
Auto/Off/On
Switch
Figure 30 - Auto/Off/On Switch
All manuals and user guides at all-guides.com