SuperiorFireplaces.us.com
126871-01B
12
INSTALLATION
Continued
WARNING: If pre-wiring, do not
connect wiring to any electrical source
at this time.
Install fi replace electrical outlet and
connect wiring to outlet before connect-
ing to electrical source. The fi replace
electrical outlet is included with the
GA3450T blower accessory.
Only use the fi replace electrical outlet
supplied with the GA3450TA blower
accessory.
2. If installing GA3450TA blower accessory,
do so at this time. See
Installing Blower
Accessory GA3450TA,
Page 15
.
NOTE
: If not installing blower accessory,
you may wish to run electrical wiring to
your fi replace for future blower installation
(see Accessories,
Page 31
) Use only ap-
proved three-wire electrical wiring.
NOTE
: A qualifi ed installer should make
all electrical connections.
3. Install gas piping to fi replace location. This
installation includes an approved
fl exible
gas line (if allowed by local codes) after
the equipment shutoff valve. The fl exible
gas line must be the last item installed on
the gas piping.
4. If you have not assembled fi rebox, follow
instructions on
Page 6
.
5. Carefully set fi replace in front of rough
opening with back of fi replace inside wall
opening.
6. Attach fl exible gas line to fi replace gas
regulator. See
Connecting to Gas Supply,
Page 18
.
7. Bend four nailing fl anges on outer casing
with pliers
(see
Figure 10
).
8. Attach fi replace to wall studs using nails
or wood screws through holes in nailing
fl ange.
9. Check all gas connections for leaks. See
Checking Gas Connections
,
Page 20
.
10. If using optional trim kit, install the trim
after fi nal fi nishing and/or painting of wall.
See instructions included with trim acces-
sory for attaching trim.
IMPORTANT
:
When fi nishing your fi rebox,
combustible materials such as wall board,
gypsum board, sheet rock, drywall, plywood,
etc. may be butted up next to the sides and top
of the fi rebox. Combustible materials should
never overlap the fi rebox front facing.
Actual
Framing
Height
26"
26-7/8"
Front Width
26-3/4"
26-7/8"
Depth
9-1/2"
10-1/2"
Bottom
3/4"
3/4"
1. Frame in rough opening. Use dimensions
shown in
Figure 8, Page 12
, for the rough
opening.
If installing in a corner, use dimensions
shown in
Figure 9, Page 12
, for the rough
opening. The height is 26-7/8" which is the
same as the wall opening above.
BUILT-IN FIREPLACE
INSTALLATION
Built-in installation of this fi replace involves
installing fi replace into a framed-in enclosure.
This makes the front of fi replace fl ush with
wall. An optional trim kit accessory is available
(see Accessories,
Page 31
).
Trim will extend
past sides of fi replace approximately 1/2".
This will cover the rough edges of the wall
opening. If installing a built-in mantel above
the fi replace you must follow the clearances
shown in
Figure 11, Page 14
. Follow the
instructions below to install the fi replace in
this manner.
All manuals and user guides at all-guides.com