Right
Side
36"
Minimum
LOCATING FIREPLACE
WARNING: Maintain the
minimum clearances shown
in
Figures 6 and 7
. If you can,
provide greater clearances from
fl oor, ceiling, and joining wall.
You can recess fi rebox into the wall. You can
also position fi replace in the optional cabinet
or corner mantels.
IMPORTANT
:
Only use
optional cabinet or corner mantels specifi ed
in this manual. Purchase the optional mantel
from your dealer
(see Accessories,
Page 31
).
INSTALLATION
Continued
Figure 7 - Mounting Clearances As
Viewed From Front of Fireplace Shown
with Optional Mantel
6"
Minimum
From
Sides Of
Fireplace
Left
Side
CEILING
36"
Minimum
FLOOR
Right
Side
0” Minimum To Top Surface Of Carpeting,
Tile Or Other Combustible Material
0" Minimum To Top Surface Of Carpeting,
Tile Or Other Combustible Material
Figure 6 - Mounting Clearances As
Viewed From Front of Fireplace Shown
Built-In the Wall
NOTE
: When installing fi replace directly on
carpeting, tile or other combustible material,
other than wood fl ooring, the fi replace shall be
installed on a metal or wood panel extending
the full width and depth of the fi replace.
CAUTION: If you install the
fi replace in a home garage
• fi replace pilot and burner must
be at least 18" above fl oor.
• locate fi replace where moving
vehicle will not hit it.
For convenience and effi ciency, install fi replace
• where there is easy access for operation,
inspection, and service.
• in coldest part of room.
An optional blower kit is available from your
dealer
(see Accessories,
Page 31
)
. If plan-
ning to use blower, locate fi replace near an
electrical outlet.
Maintain adequate clearances for accessibility for purposes
of servicing and proper operation.