SuperiorFireplaces.us.com
126871-01B
17
INSTALLATION
Continued
Figure 18 - Installing Switch Plate to
Valve Cover Shield
Switch
Plate
Screw
Valve Cover
Shield
For Built-In Installation
WARNING: A licensed elec-
trician must connect the wiring
harness to electrical supply
following all local codes. Electri-
cian must provide a clamp on the
box cover to secure the wiring.
Wiring should be routed through
the bushing in the hole on the
outer casing of heater.
Follow instructions for
Removing Valve Cover
Shield,
Page 15
. Continue installation as
follows:
1. Install a snap bushing found in hardware
kit into one of the holes found on rear of
valve cover shield. The other hole is for a
strain relief clamp (not supplied) to secure
incoming electrical supply.
2. Follow steps 2 through 6 in
Installing
Blower Assembly
,
Page 16
. Also remove
black wire from middle switch terminal 2.
3. Remove black plastic strain relief and power
cord from switch plate. The power cord
supplied will not be used in built-in installa-
tions. Pop in the plastic snap bushing found
in hardware kit into the hole left by supply
cord/strain relief.
4. A licensed electrician must follow the wir-
ing diagram to connect incoming electri-
cal supply to fan kit wiring harness
(see
Figure 19
).
5. Plug power cord to the outlet receptacle
(not provided) as shown in
Figure 18
.
Wind the extra power cord and tie it up
with the plastic wire strap
(see
Figure
20, Page 18
)
. Set the power cord bundle
between the burner bracket and outer
casing, away from the burner.
6. Reinstall valve cover shield.
7. Test to make sure the blower is working
properly.
8. Reinstall upper louver assembly and hood
if previously removed,
(see
Figure 15,
Page 15
)
. Close lower louver door.
Red
Red
Fan Switch
(Auto/Of
f/On)
Blue
Blue
Thermostat
Switch
(N.O.)
Green
White
Green
White
On
11
0/1
1
5
V.
A
.C.
Blower
Motor
Black
Of
f
1
2
3
Auto
Figure 19 - Wiring Diagram For Blower
Accessory Built-In Installation
NOTE
: When switch is in AUTO position,
fan will start after heater has run for a
few moments. Fan will continue to run
for several moments after heater has
been turned off. When switch is in the ON
position, fan will run until turned to OFF.
Reinstall upper louver assembly and hood
if previously removed, (see
Figure 15,
Page 15
). Close lower louver door.
WARNING: Caution: Label all wires
prior to disconnection when servicing
controls. Wiring errors can cause
improper and dangerous operation.
Verify proper operation after servicing.
All manuals and user guides at all-guides.com