OPERATION & MAINTENANCE MANUAL SWE215F
153
4.5.7.6 Cleaning Cooler
For details, please refer to chapter 4.5.3.2.
4.5.8 Every 1000 Hours Maintenance
When the machine works for every 1000 hours, take the
maintenance as specified in this chapter and carry out
maintenance of every 50 hours, every 100 hours and every
250 hours and every 500 hours at the same time.
4.5.8.1 Replacing Swing Reduction Gear Oil (6.6L)
Stop the machine at level ground.
Stop auto-idle switch, run the engine unloaded at low
speed for 5 minutes.
【
Important
】
Stopping the engine improperly may damage
turbocharger.
Set start key to OFF position, stop the engine, remove
the key from starting lock, set pilot safety lever to
LOCK position.
Note
After completing work, the gear oil temperature
might be very high, wait for temperature to cool
down.
Place a container under drain pipe to collect oil.
Loosen drain plug to drain the oil, and then tighten the
plug.
Remove oil fill end cover, add specified gear lubricate
oil.
Remove dipstick of swing redactor, wipe off oil with
clean cloth, re-insert dipstick, then pull out again, the
mark of oil should be between two scales.
If the oil level doesn’t reach mark L, add oil through
oil fill port, if the oil level exceeds mark H, drain
excessive engine oil and check oil level again.
Summary of Contents for SWE215F-5
Page 137: ...OPERATION MAINTENANCE MANUAL SWE215F 130 4 4 10 Hoses...
Page 170: ...OPERATION MAINTENANCE MANUAL SWE215F 163 5 TECHNICAL SPECIFICATION...
Page 174: ...OPERATION MAINTENANCE MANUAL SWE215F 167 5 1 4 SWE215F 5 Electrical Schematic...
Page 176: ...OPERATION MAINTENANCE MANUAL SWE215F 169 5 1 6 SWE215F 5 Hydraulic Schematic...
Page 178: ...OPERATION MAINTENANCE MANUAL SWE215F 171 6 NOTE FOR SAFETY...