OPERATION & MAINTENANCE MANUAL SWE215F
151
MPa,
2kgf/cm2
)
, scatter personnel around to avoid
scattered
broken
pieces,
wear
personal
protective articles including goggles and
protective glassed.
Use compressed air to clean outside filter (1),
following the wrinkle direction to blow air outward.
Clean up the inside filter.
Install outside filter (1), end cover, fasten clamp
buckle (2).
Start engine; run it unloaded at low speed. Check filter
clogging indicator on monitor. If this indicator
illuminates, shut engine immediately and replace
outside filter (1).
Replace internal filter element (3) the moment outside
filter element (1) is replaced.
4.5.6.5 Checking Hoses and Pipeline Leakage, Interference wear-out.
For details, please refer to chapter 4.5.1.6.
4.5.7 Every 500 Hours Maintenance
When the machine works for every 500 hours, take the
maintenance as specified in this chapter and carry out
maintenance of every 50 hours, every 100 hours and 250
hours at the same time.
4.5.7.1 Greasing Ball Track of Swing Bearing
Stop the machine at level ground, lower the bucket at
level ground.
Shut auto-idle speed switch, run the engine unloaded
at low speed for 5 minutes.
【
Important
】
Stopping the engine improperly may damage
turbocharger.
Set start key to OFF position, stop the engine, remove
the key from starting lock, set pilot safety lever to
LOCK position.
Pump in grease through 3 grease fittings to swing
bearing ball track.
Start engine, lift bucket, and swing upper-structure at
Summary of Contents for SWE215F-5
Page 137: ...OPERATION MAINTENANCE MANUAL SWE215F 130 4 4 10 Hoses...
Page 170: ...OPERATION MAINTENANCE MANUAL SWE215F 163 5 TECHNICAL SPECIFICATION...
Page 174: ...OPERATION MAINTENANCE MANUAL SWE215F 167 5 1 4 SWE215F 5 Electrical Schematic...
Page 176: ...OPERATION MAINTENANCE MANUAL SWE215F 169 5 1 6 SWE215F 5 Hydraulic Schematic...
Page 178: ...OPERATION MAINTENANCE MANUAL SWE215F 171 6 NOTE FOR SAFETY...