4
procedures, please refer to the “diesel engine
maintenance manual” enclosed with the other
literature of the machine.
Pre-start inspection
Keep control lever of pilot valve in LOCK position,
pilot handle and travel pull link are in normal position
(neutral position), operator sit over seat.
While switching the key to ON position, except engine
hour meter and LCD module, all indicators of test
system must light up. Buzzer must sound as well.
Self-test is finished in 2 seconds to indicate test
system is or is not properly functioning.
Start the engine
Keep control lever of pilot valve at LOCK position.
Switch key to ON position.
Honk the horn to alert the persons around.
Turn the key to the right; hold it in START position
until engine runs. Then release the key, switch will
automatically. Return to ON position.
Caution
Do not operate motor for longer than 5 seconds
ever time to avoid damage to machine. In case
of failure to start engine, switch the key back to
OFF position, wait 2 minutes before a new
attempt. Incorrect start may damage to starter.