Therefore, if a communication error shows up on the display:
1. Check if your data cable is the correct type.
2. Check if you are plugging the cable into the correct sockets. Usually, RS 485 is employed, but some
battery manufacturers use others.
It is important to always refer to the documentation of the battery manufacturers when installing the
battery. Below there is a list of batteries that has been examined, tested, and approved by Sunsynk.
Brand
Model
RS485 or
CAN
Inverter
Setup
Notes
Pylon or
Equivalent
US2000
CAN
0
RS485
5
US20000-PLUS
CAN
0
RS485
5
DYNESS
B4850
CAN
0
Short Lione 6&7 at inverter
side
POWERBOX F
CAN
0
CCGX
48Vxxxx
CAN
0
Need confirm CAN_H
CAN_L
SACRED SUN
48Vxxxx
RS485
1
Cut Line 3, 6, 8
SOLAX
48Vxxxx
CAN
0
KOK
48Vxxxx
RS485
2
UZ ENERGY
UZ-EB51.2-100-
A11
CAN
0
Topakpower
48Vxxxx
RS485
4
Hai Ying
HY48050
CAN
0
Re-Power
LS4850
CAN
0
NOTE
Some types of lithium battery the BMS cannot be controlled by Sunsynk inverter. In this case, treat
the battery as a lead-acid type and set the charging and discharging protocol following the battery
manufacturer specification.