14
Hybrid Parity (Super) Inverter 3.6kW/5.5kW/8.8kW Plus Parallel Version
www.sunsynk.com
``
3.4. AC Connection
– Single Inverter or Multi Inverter System
Bottom view of the 3.6kW/5.5kW model
Bottom view of the 8kW model
All wiring and cable sizing must be following the country wiring regulations and code of
practices.
Ensure that suitable disconnection devices and RCDs are fitted.
NOTES
Depending on the battery type, the inverter should be capable of controlling the batteries BMS.
Therefore, you need to set the protocol of the BMS on both the battery and the inverter.
WHEN USING MORE THAN ONE BATTERY, THE FIRST BATTERY WILL BE THE MASTER,
AND THE OTHER BATTERIES WILL BE THE SLAVES. PLEASE, CHECK THE BATTERY
MANUFACTURER SPECIFICATION FOR PROPER OPERATION.
To verify if the battery is actually communicating access the Li BMS menu as detailed in section
4.13 “Setting Up a Lithium Battery” and check whether the values are realistic or not. It is important
that the charge and discharge limits in that page match the numbers expected for the number of
batteries physically connected.