![Sunfar V260-4T0007G/4T0011P User Manual Download Page 32](http://html1.mh-extra.com/html/sunfar/v260-4t0007g-4t0011p/v260-4t0007g-4t0011p_user-manual_1396025032.webp)
Wiring Of Frequency Inverter
V260 Series High Performance Closed-Loop Vector Inverter User Manual
24
4.3 WIRING OF CONTROL TERMINAL
4.3.1 WIRING OF CONTROL PANEL STANDARD TERMINAL CON1
、
CON2
、
CON3
、
CON4
4.3.2 FUNCTION DESCRIPTION OF CONTROL TERMINAL
Type
Label of
terminal
Name
Function description of terminal
Specification
Control
terminal
DI1—CM
Multifunctional input
terminal DI1
6 ways of programmable switching
value input terminal can be selected
99 kinds of operational control
commands by function code in F3.0
group by programming.
See Reference Table for Input
Function Selection of Multifunctional
Terminal for detail.
Optical coupler
isolated input :
24Vdc /5mA
Doorsill voltage :
<16V
Bandwidth
<
1MHZ
DI2—CM
Multifunctional input
terminal DI2
DI3—CM
Multifunctional input
terminal DI3
DI4—CM
Multifunctional input
terminal DI4
DI5—CM
Multifunctional input
terminal DI5
DI6—CM
Multifunctional input
terminal DI6
Operating
status
output
CM
Common terminal of
input/output terminal
2 ways of programmable open
collector output and 1 way of
programmable relay output
terminal can be selected 71 kinds
of operating status output by the
function code in F3.1 group by
programming. See Reference
Table for Monitor Unit Variables
for detail.
Maximum load
current is 150mA;
The highest
withstand voltage is
24V.
DO1—CM
Multifunctional
output terminal DO1
DO2—CM
Multifunctional
output terminal DO2
TA
Multifunctional relay
output TA-TB
normally closed
TA-TC normally
open
Contact capacity:
AC250V/2A
TB
TC
Power
supply
CM
+24V power supply
reference place
Power supply of switching value
terminal
Maximum output
current:100mA
24V
+24V power supply
Analog
input
AI1—GND Analog
input
AI1
Select input voltage range, polarity
and other functions with function
code in F4 Group.
Input voltage:
0-10V,
Input
impendance: 100K
Input current:
0-20mA
AI2—GND Analog
input
AI2
DI1
DI2 DI3
DI4
DI5 24V CM
AI1
AI2
VS GND DO1 CM
TC
TB
TA AO1
CON3
CON4
Type I
:
CON3 and CON4 terminals
suitable model: inverter model below
V260-4T0022G/4T0030P
Type II
:
CON1 and CON2 terminals
suitable model: inverter model above
V260-4T0030G/4T0040P
DI1
DI3 DI5 DO1 24V AI1 AO1 VS
DI2
DI4
DO2 CM AI2 AO2 GND
TA
TB
TC
DI6
CON2
CON1