![Sunfar V260-4T0007G/4T0011P User Manual Download Page 146](http://html1.mh-extra.com/html/sunfar/v260-4t0007g-4t0011p/v260-4t0007g-4t0011p_user-manual_1396025146.webp)
138 Description Of Specific Functions
V260 Series High Performance Closed-Loop Vector Inverter User Manual
44~45: Counter clock terminal
This function terminal is used for counter clock inputting.
46~47: Counter trigger signal
This terminal is used as counter trigger end.
48~49: Counter resetting terminal
This terminal is used for counter resetting signal inputting.
50~51: Counter auto control signal
This terminal is used for counter gated signal inputting.
52~54: Timer trigger signal
This terminal is used as timer trigger end.
55~57: Timer resetting
This terminal is used for timer resetting signal inputting.
58~60: Timer gated signal
This terminal is used for timer gated signal inputting.
61: Single pulse accumulative length value
This terminal is used for single pulse accumulative length value resetting.
62: Motor temperature detection contact input
When thermo switch is used as the external temperature transmitter (see parameter F5.4.43 specification),
this terminal is used for external thermo switch inputting.
63~64: Compensation PID parameter selection
When [F9.1.21] = # # 3 3, this terminal is used for controller parameter of compensation PID selecting.
Table 7-14 Parameter selecting table for compensation PID
Compensation PID parameter
selection 2
Compensation PID parameter
selection 1
PID effective parameter group
OFF OFF
Group
1
(F9.0.03~F9.0.07)
OFF ON
Group
2
(F9.1.29~F9.1.33)
ON
OFF
Group 3 ( F9.1.34~F9.1.38)
ON ON
Group
4
(F9.1.39~F9.1.43)
65: Magnetic flux brake effective
It is applied to magnetic flux brake function input and removal during the deceleration halt process.
66: Position pulse counting resetting
Adjust the position pulse counting to zero, which is used for position origin preset default counting.
67: Automatic shifting jog
It is the machinery shifting dedicated function of the spindle or machinery variable speed gear. When this
function is invalid, frequency drive system will operate both sides alternatively at certain period or revolving
speed/moment of force so as to achieve the machinery shifting, avoiding the dead( relative function
parameter: Fb.2.18, Fb.2.19).
68: Servo pulse command direction
This function is valid when pulse input port (DI9//Fin) is used as servo command pulse, and representative
pulse direction is: invalid is positive (add plus), valid is negative (minus pulse).