![Sunfar V260-4T0007G/4T0011P User Manual Download Page 235](http://html1.mh-extra.com/html/sunfar/v260-4t0007g-4t0011p/v260-4t0007g-4t0011p_user-manual_1396025235.webp)
EMC
227
V260 Series High Performance Closed-Loop Vector Inverter User manual
•
Insulation resistance: iron core-winding 1000VDC, insulation resistance
≥
100M
Ω;
•
Reactor noise is less than 70dB (test at the point of 1m horizontal distance with
reactor)
;
•
Temperature rise is less than 70K.
2, Parameter Configuration of AC Input Reactor
Inverter Power
(KW)
Reactor Model
Size
L*W*H (mm)
Mounting
Dimension
(mm)
Installation
Terminal Aperture
(mm)
0.7 AKSG10A/5V
140*85*140 75*55
Φ
6
1.1 AKSG10A/5V
140*85*140 75*55
Φ
6
1.5 AKSG10A/5V
140*85*140 75*55
Φ
6
2.2 AKSG10A/5V
140*85*140 75*55
Φ
6
3.0 AKSG10A/5V
140*85*140 75*55
Φ
6
4.0 AKSG15A/5V
140*85*140 75*55
Φ
6
5.5 AKSG15A/5V
140*85*140 75*55
Φ
6
7.5 AKSG20A/5V
175*130*140 82*75
Φ
6
9.0 AKSG30A/5V
175*130*140 82*75
Φ
6
11 AKSG30A/5V
175*130*140 82*75
Φ
6
15 AKSG40A/5V
210*120*190
110*70
Φ
8
18.5 AKSG50A/5V
210*120*190 110*70
Φ
8
22 AKSG60A/5V
210*165*170
110*85
Φ
8
30 AKSG80A/5V
210*165*170
110*85
Φ
8
37 AKSG110A/5V
210*165*170 110*85
Φ
8
45 AKSG125A/5V
210*165*170 110*85
Φ
8
55 AKSG150A/5V
270*170*220 155*85
Φ
10
12.4.4 AC OUTPUT REACTOR
AC output reactor is mounted at output terminal of inverter to restrain capacitive
charging current of connecting cable between inverter and motor, voltage built-up rate of
PWM wave of passivated inverter, improve power factor and quality of power grid as well
as stabilize waveform.