64
Process Conditions
Do process conditions; suction pressure, suction temperature, discharge header pressure, and mole
weight agree with specification sheet information? Check with your Sundyne Corporation
representative if you must test a different gas than shown on the specification sheet.
Auxiliary Lube Pump
If you have an auxiliary lubrication pump, unlock the electrical circuit and start it in the “hand” position.
Check for oil leaks and recheck the oil level.
Piping Connections
Are the following bolted/threaded connections tight:
a. Compressor flange bolts?
b. Seal environment piping and port connections?
c. Cooling water connections to heat exchanger? (if applicable)
d. Gearbox oil drain plug?
e. Compressor case drain plug?
Reference B
Lock-out/Tag-out Guidelines
Follow Your Companies Lock-Out / Tag-Out Procedure When Servicing Sundyne
Compressors.
Never remove a lock or tag applied by someone else. Additional locks or tags should be applied if
multiple groups are working on the equipment. Each responsible work group leader should apply a
lock or tag. Always treat conductors and equipment as if they are energized.
Reference C
Seal Arrangement Drawings for Single, Double and Tandem Configurations
Summary of Contents for LMC 341F
Page 32: ...28 Figure 5 1 Compressor Cross Section and Clearances ...
Page 69: ...65 SINGLE SEAL ARRANGEMENT ...
Page 70: ...66 DOUBLE SEAL ARRANGEMENT ...
Page 71: ...67 TANDEM SEAL ARRANGEMENT ...
Page 73: ...69 Phoenix Compressor Gearbox Cross Sectional View ...
Page 74: ...70 ...
Page 75: ...71 PHOENIX GEARBOX MODULE DRAWING GB01AY01 ...
Page 76: ...72 ...
Page 77: ...73 ...
Page 78: ...74 ...
Page 79: ...75 ...
Page 80: ...76 ...
Page 81: ...77 ...