4-92
Sun Fire B1600 Blade System Chassis Switch Administration Guide • June 2003
Syntax
switchport broadcast packet-rate
rate
no switchport broadcast
rate
– The threshold level in packets per second. (Range: 16, 64, 128, 256)
Default Setting
Enabled for all ports
256 packets per second
Command Mode
Interface Configuration (Ethernet)
Command Usage
■
When broadcast traffic exceeds the specified threshold, packets above that
threshold are dropped.
■
This command can enable or disable broadcast storm control for the selected
interface. However, the specified threshold value applies to the entire switch.
■
Down-link ports SNP0-15 are fixed with broadcast storm control enabled.
Example
The following shows how to configure broadcast suppression at 64 packets per
second:
Note –
The
switchport broadcast
command enables broadcast storm control on
the specified interface, but it sets the broadcast threshold for every interface on the
switch.
Console(config)#
interface ethernet SNP5
Console(config-if)#
switchport broadcast packet-rate 64
Console(config-if)#
Summary of Contents for Sun Fire B1600 Administration
Page 4: ......
Page 17: ...Contents xvii Glossary Glossary 1 Index Index 1 ...
Page 18: ...xviii Sun Fire B1600 Blade System Chassis Switch Administration Guide June 2003 ...
Page 38: ...2 6 Sun Fire B1600 Blade System Chassis Switch Administration Guide June 2003 ...
Page 47: ...Chapter 3 General Management of the Switch 3 9 FIGURE 3 3 Switch Setup System Identity Window ...
Page 198: ...3 160 Sun Fire B1600 Blade System Chassis Switch Administration Guide June 2003 ...
Page 372: ...A 4 Sun Fire B1600 Blade System Chassis Switch Administration Guide June 2003 ...
Page 392: ...C 6 Sun Fire B1600 Blade System Chassis Switch Administration Guide June 2003 ...
Page 398: ...Glossary 6 Sun Fire B1600 Blade System Chassis Switch Administration Guide April 2003 ...
Page 402: ...Index 4 Sun Fire B1600 Blade System Chassis Switch Administration Guide January 2003 ...