4-66
Sun Fire B1600 Blade System Chassis Switch Administration Guide • June 2003
4.3.6.4
exec-timeout
Use this command to set the interval that the system waits for user input before
terminating the current session. Use the
no
form to restore the default.
Syntax
exec-timeout
[
seconds
]
no exec-timeout
seconds
- Integer that specifies the number of seconds.
(Range: 0 - 65535 seconds; 0: no timeout)
Default Setting
CLI: No timeout
Telnet: 10 minutes
Command Mode
Line Configuration
Command Usage
■
If user input is detected within the timeout interval, the session is kept open;
otherwise the session is terminated.
■
This command applies to both the serial console and Telnet connections (but
you cannot disable the timeout for Telnet).
Example
To set the timeout to two minutes, enter this command:
4.3.6.5
password-thresh
Use this command to set the password intrusion threshold that limits the number of
failed login attempts. Use the
no
form to remove the threshold value.
Console(config-line)#
exec-timeout 120
Console(config-line)#
Summary of Contents for Sun Fire B1600 Administration
Page 4: ......
Page 17: ...Contents xvii Glossary Glossary 1 Index Index 1 ...
Page 18: ...xviii Sun Fire B1600 Blade System Chassis Switch Administration Guide June 2003 ...
Page 38: ...2 6 Sun Fire B1600 Blade System Chassis Switch Administration Guide June 2003 ...
Page 47: ...Chapter 3 General Management of the Switch 3 9 FIGURE 3 3 Switch Setup System Identity Window ...
Page 198: ...3 160 Sun Fire B1600 Blade System Chassis Switch Administration Guide June 2003 ...
Page 372: ...A 4 Sun Fire B1600 Blade System Chassis Switch Administration Guide June 2003 ...
Page 392: ...C 6 Sun Fire B1600 Blade System Chassis Switch Administration Guide June 2003 ...
Page 398: ...Glossary 6 Sun Fire B1600 Blade System Chassis Switch Administration Guide April 2003 ...
Page 402: ...Index 4 Sun Fire B1600 Blade System Chassis Switch Administration Guide January 2003 ...