Chapter 4
Replacing Motherboard Assembly Components
4-7
FIGURE 4-4
Removing PCI-X 4 and PCIe 5 Cards From the PCI Mezzanine
Set the card aside on an antistatic mat.
5. Consider your next step:
■
If you are replacing the card, continue to
“To Install PCI-X 4 and PCIe 5 Cards” on
page 7
.
■
If you do not replace the card, install a filler panel.
6. Tighten the card securing screws.
7. Bring the server back online. See
Section 4.1, “Powering Off and Powering On
the Server” on page 4-1
.
▼
To Install PCI-X 4 and PCIe 5 Cards
1. Prepare the server for PCI card installation. See
Section 4.1, “Powering Off and
Powering On the Server” on page 4-1
.
2. With the PCI mezzanine installed and cabled, determine which slot to install
the card and loosen the appropriate card securing screws (
FIGURE 4-3
).
3. Remove the replacement card from its packaging and place it onto an antistatic
mat.
4. If a filler panel is installed, remove it by pulling the tab.