1.6.1
Identifying PSH Detected Faults
When a PSH fault is detected, a Solaris console message similar to
EXAMPLE 1-8
is
displayed.
Faults detected by the Solaris PSH facility are also reported through service processor
alerts.
EXAMPLE 1-9
depicts an ALOM CMT CLI alert of the same fault reported by
Solaris PSH in
EXAMPLE 1-8
.
The ALOM CMT CLI
showfaults
command provides summary information about
the fault. See
Section 1.4.4, “Displaying System Faults” on page 1-21
for more
information about the
showfaults
command.
Note –
The Service Required LED is also turns on for PSH diagnosed faults.
1.6.1.1
Using the
fmdump
Command to Identify Faults
The
fmdump
command displays the list of faults detected by the Solaris PSH facility
and identifies the faulty FRU for a particular EVENT_ID (UUID).
Do not use
fmdump
to verify a FRU replacement has cleared a fault because the
output of
fmdump
is the same after the FRU has been replaced. Use the
fmadm
faulty
command to verify the fault has cleared.
EXAMPLE 1-8
Console Message Showing Fault Detected by PSH
SUNW-MSG-ID: SUN4V-8000-DX, TYPE: Fault, VER: 1, SEVERITY: Minor
EVENT-TIME: Wed Sep 14 10:09:46 EDT 2005
PLATFORM: SUNW,Sun-Netra-T5220, CSN: -, HOSTNAME: hostname
SOURCE: cpumem-diagnosis, REV: 1.5
EVENT-ID: f92e9fbe-735e-c218-cf87-9e1720a28004
DESC: The number of errors associated with this memory module has exceeded
acceptable levels.
AUTO-RESPONSE: Pages of memory associated with this memory module are being
removed from service as errors are reported.
IMPACT: Total system memory capacity will be reduced as pages are retired.
REC-ACTION: Schedule a repair procedure to replace the affected memory module.
Use fmdump -v -u <EVENT_ID> to identify the module.
EXAMPLE 1-9
ALOM CMT CLI Alert of PSH Diagnosed Fault
SC Alert: Host detected fault, MSGID: SUN4V-8000-DX
Summary of Contents for Netra T5220
Page 1: ...Sun Netra T5220 Server Service Manual Part No E21359 02 January 2012...
Page 14: ...1 4 Sun Netra T5220 Server Service Manual January 2012 FIGURE 1 1 Diagnostic Flowchart...
Page 156: ...5 26 Sun Netra T5220 Server Service Manual January 2012...
Page 171: ...Appendix A Signal Pinouts A 7...
Page 172: ...A 8 Sun Netra T5220 Server Service Manual January 2012...