1-30
Sun Netra T5220 Server Service Manual • January 2012
TABLE 1-8
shows typical combinations of ALOM CMT CLI variables and associated
POST modes.
1.5.2
Changing POST Parameters
1. Access the ALOM CMT CLI
sc>
prompt:
At the console, issue the
#.
key sequence:
2. Use the ALOM CMT CLI
sc>
prompt to change the POST parameters.
Refer to
TABLE 1-7
for a list of ALOM CMT CLI POST parameters and their values.
The
setkeyswitch
parameter sets the virtual keyswitch, so this parameter does
not use the
setsc
command. For example, to change the POST parameters using
the
setkeyswitch
command, enter the following:
TABLE 1-8
ALOM CMT CLI Parameters and POST Modes
Parameter
Normal Diagnostic Mode
(Default Settings)
No POST Execution
Diagnostic Service
Mode
Keyswitch Diagnostic
Preset Values
diag_mode
normal
off
service
normal
setkeyswitch
*
* The
setkeyswitch
parameter, when set to
diag
, overrides all the other ALOM CMT CLI POST variables.
normal
normal
normal
diag
diag_level
max
n/a
max
max
diag_trigger
power-on-reset
error-reset
none
all-resets
all-resets
diag_verbosity
normal
n/a
max
max
Description of POST
execution
This is the default POST
configuration. This
configuration tests the
system thoroughly, and
suppresses some of the
detailed POST output.
POST does not
run, resulting in
quick system
initialization. This
is not a suggested
configuration.
POST runs the full
spectrum of tests
with the maximum
output displayed.
POST runs the full
spectrum of tests
with the maximum
output displayed.
#.
sc>
setkeyswitch diag
Summary of Contents for Netra T5220
Page 1: ...Sun Netra T5220 Server Service Manual Part No E21359 02 January 2012...
Page 14: ...1 4 Sun Netra T5220 Server Service Manual January 2012 FIGURE 1 1 Diagnostic Flowchart...
Page 156: ...5 26 Sun Netra T5220 Server Service Manual January 2012...
Page 171: ...Appendix A Signal Pinouts A 7...
Page 172: ...A 8 Sun Netra T5220 Server Service Manual January 2012...