1-36
Sun Netra T5220 Server Service Manual • January 2012
1. After replacing a faulty FRU, at the ALOM CMT CLI prompt use the
showfaults
command to identify POST detected faults.
POST detected faults are distinguished from other kinds of faults by the text:
Forced fail
, and no UUID number is reported.
Example:
If no fault is reported, you do not need to do anything else. Do not perform the
subsequent steps.
2. Use the
enablecomponent
command to clear the fault and remove the
component from the ASR blacklist.
Use the FRU name that was reported in the fault in
Step 1
.
The fault is cleared and should not show up when you run the
showfaults
command. Additionally, the Service Required LED is no longer on.
3. Power cycle the server.
You must reboot the server for the
enablecomponent
command to take effect.
4. At the ALOM CMT CLI prompt, use the
showfaults
command to verify that
no faults are reported.
EXAMPLE 1-6
POST Detected Fault
sc>
showfaults
Last POST Run: Wed Jun 27 21:29:02 2007
Post Status: Passed all devices
ID FRU Fault
0 /SYS/MB/CMP0/BR2/CH0/D0 SP detected fault: /SYS/MB/CMP0/BR2/CH0/D0 Forced
fail (POST)
EXAMPLE 1-7
Using the
enablecomponent
Command
sc>
enablecomponent /SYS/MB/CMP0/BR2/CH0/D0
TABLE 1-9
Verifying Cleared Faults Using the
showfaults
Command
sc>
showfaults
Last POST run: THU MAR 09 16:52:44 2006
POST status: Passed all devices
No failures found in System
Summary of Contents for Netra T5220
Page 1: ...Sun Netra T5220 Server Service Manual Part No E21359 02 January 2012...
Page 14: ...1 4 Sun Netra T5220 Server Service Manual January 2012 FIGURE 1 1 Diagnostic Flowchart...
Page 156: ...5 26 Sun Netra T5220 Server Service Manual January 2012...
Page 171: ...Appendix A Signal Pinouts A 7...
Page 172: ...A 8 Sun Netra T5220 Server Service Manual January 2012...