5-12
Sun Netra T5220 Server Service Manual • January 2012
FIGURE 5-11
Lifting Out the Hard Drive Fan Assembly
6. Set the hard drive fan assembly aside on an antistatic mat.
7. Continue to
Section 5.4.2, “Installing the Hard Drive Fan Assembly” on page 5-12
.
5.4.2
Installing the Hard Drive Fan Assembly
1. Remove the replacement hard drive fan assembly from its packaging and place
it on an antistatic mat.
2. Lower the hard drive fan assembly, and slide the hard drive fan bracket back so
that the tabs enter the slots (
FIGURE 5-12
).
3. Pivot the hard drive fan bracket toward rear of server until it clicks.
4. Connect the hard drive fan assembly cable to the power board (
FIGURE 5-12
).