4-30
Sun Netra T5220 Server Service Manual • January 2012
4. Gain access to the ALOM CMT
sc>
prompt.
5. Run the
showfaults
command.
■
If the fault was detected by the host and the fault information persists, the
output will be similar to the following example:
■
If the
showfaults
command does not report a fault with a UUID, then you do
not need to proceed with the following steps because the fault is cleared.
6. Run the
clearfault
command.
7. Switch to the system console.
8. Issue the
fmadm repair
command with the UUID.
Use the same UUID that you used with the
clearfault
command.
4.7
Replacing the Battery
4.7.1
Removing the Battery
1. Prepare the server for battery removal. See
Section 4.1, “Powering Off and
Powering On the Server” on page 4-1
.
sc>
showfaults
Last POST Run: Wed Jun 29 11:29:02 2007
Post Status: Passed all devices
ID FRU Fault
0 /SYS/MB/CMP0/BR2/CH1/D0 Host detected fault, MSGID:
SUN4V-8000-DX UUID: 7ee0e46b-ea64-6565-e684-e996963f7b86
sc>
clearfault 7ee0e46b-ea64-6565-e684-e996963f7b86
sc>
console
#
fmadm repair 7ee0e46b-ea64-6565-e684-e996963f7b86